Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MM-L-751 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
55 | 5510 | 005506847 | A173A0 | 34668 | X | 4 | 3 | A | N | A | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
FGGI | 1 | G | Z | TG | 1 Mar 2006 | |||||||||||||||||||||||||
N9BZ | 1 | G | Z | GH | JN | 1 Mar 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 4 | 1 | E | AX | C | MM-L-751 | 81348 |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43216-5000
The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
559 | Z | 9 | A | B | Z | W | 112870 | Z | 58410 | LUMBER-OR-WOOD-OR-PLYWOOD |
Lumber, Untreated, Softwood, (less than 35 feet) (See 850)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Board Foot - A unit of measure for lumber equal to the volume of a board 12” X 12” X 1”.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CRXX | Measuring Method And Length | 1.000 FEET MINIMUM RANDOM |
ZZZT | Nondefinitive Spec/Std Data | 3 TABLE |
CQMP | Preservative Solution Type | AMMONIACAL COPPER ARSENITE OR CHROMATED COPPER ARSENATE, TYPE I, II OR III OR COAL-TAR CREOSOTE OR CREOSOTE COAL-TAR SOLUTION OR CREOSOTE PETROLEUM SOLUTION OR PENTACHLOROPHENOL IN HEAVY PETROLEUM SOLVENT |
CRJD | Random Length | 10 FT AND LONGER WITH A MAX OF 10 PCT TO BE 10 FT LONG AND A MIN OF 50 PCT TO BE 14 FT AND LONGER |
CSTZ | Service Usage | TIMBERS AND IMPORTANT STRUCTURAL MEMBERS IN CONTACT WITH GROUND OR FRESH WATER |
BMKY | Treatment Type | PRESERVATIVE, TT-W-571 |
CSTS | Typical Wood Products Use | PRESERVATIVE TREATED HIGH QUALITY CONSTRUCTION FOR USE IN FRESH WATER OR GROUND CONTACT |
CRPW | Width-Location And Measuring Method | 2.000 INCHES NOMINAL OVERALL SPECIFIED |
CQWY | Species-Grade And Grading Association | DOUGLAS-FIR, COASTAL NO. 1 STRUCTURAL WEST COAST LUMBER INSPECTION BUREAU OR DOUGLAS-FIR, COASTAL NO. 1 WESTERN WOOD PRODUCTS ASSOCIATION OR HEMLOCK, WESTERN NO. 1 STRUCTURAL WEST COAST LUMBER INSPECTION BUREAU OR HEMLOCK, WESTERN NO. 1 WESTERN WOOD PRODUCTS ASSOCIATION OR LARCH NO. 1 WESTERN WOOD PRODUCTS ASSOCIATION OR PINE, SOUTHERN NO. 1 SR TIMBERS SOUTHERN PINE INSPECTION BUREAU |
ZZZK | Specification/Standard Data | 81348-MM-L-751 GOVERNMENT SPECIFICATION |
SUPP | Supplementary Features | TT-W-571,TABLE 1,UNIT OF ISSUE BF |
CRYQ | Surface Condition Degree | ROUGH-UNSANDED FULL LENGTH |
CSHP | Thickness-Location And Measuring Method | 6.000 INCHES NOMINAL OVERALL SPECIFIED |