5995-00-224-4743

CABLE ASSEMBLY,RADIO FREQUENCY


5995-00-224-4743 (5995002244743, 002244743)
Part Numbers (2 listings): 916510-5 | 916510 |
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 17 May 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-00-224-4743 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
916510-53 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
916510D - Drawing Number Reference9 - No Longer UsedRAYTHEON COMPANY  96214    CAGE 96214  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5995-00-224-4743 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995002244743A077A000886XKANS17 May 1973
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

002244743

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-00-224-4743

A077A0

Federal Item Identification Guide (FIIG_4065)

00886

Item Naming Code (INC_4080)

17 May 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5995-00-224-4743 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
DGX1DCX13HCX1 Feb 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

CX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Richmond, Richmond, VA 23297-5000


FLIS - SEG C - REFERENCE NUMBER | NSN 5995-00-224-4743 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332ACXD916510-5  96214   CAGE/96214
D9ACX916510  96214   CAGE/96214
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5995-00-224-4743 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6CX05 Jun 1982
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

5 Jun 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5995-00-224-4743 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA743Z9AHZP061130X34350CABLE-ASSEMBLY
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5995-00-224-4743 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-00-224-4743 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPPElectrical Resistance50.00 OHMS IMPEDANCE
CXDQConductor Arrangement And Quantity1 COAXIAL
CXCWConductor FormSOLID SINGLE CONDUCTOR
ADVLCross Section Outside Diameter0.216 INCHES NOMINAL
AAGRCross-Sectional Shape StyleROUND
AMQNConductor Quantity1
MATTMaterialCOPPER ALLOY 1ST POSITION CONDUCTOR SINGLE CONDUCTOR
MATTMaterialSILVER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR
MDCLMaterial Document And ClassificationMIL-C-17 MIL SPEC ALL MATERIAL RESPONSES 1ST POSITION CONDUCTOR ALL CONDUCTORS
PMLCPrecious Material And LocationCONDUCTOR SURFACE SILVER
PMWTPrecious Material And Weight0.040 SILVER GRAINS, TROY
PRMTPrecious MaterialSILVER
CXDCRound Conductor Size19 AWG SINGLE CONDUCTOR
AAJUOverall Length1.875 FEET
FEATSpecial FeaturesRG223U CABLE
STYLStyle DesignatorINTERNAL AND EXTERNAL CONNECTOR
CXGNTerminal Commercial And Government Entity Code81349 BOTH ENDS SINGLE CONDUCTOR
CXGGTerminal Manufacturer Identifying Reference NumberM39012-16-0001 1ST END SINGLE CONDUCTOR
CXGGTerminal Manufacturer Identifying Reference NumberM39012-16-0001 2ND END SINGLE CONDUCTOR
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR


Back to Top