6120-01-470-0634

POWER SUPPLY


6120-01-470-0634 (6120014700634, 014700634)
Part Number (1 listing): 73-190-0223
Summary

FSG 61 / FSC 6120

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 6 Dec 1999

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6120-01-470-0634 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
73-190-02233 - Design Control Reference2 - Production ItemASTEC AMERICA INC.  08742    CAGE 08742  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6120-01-470-0634 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616120014700634A3990000740X1BNAA06 Dec 1999
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6120

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Transformers: Distribution and Power Station

014700634

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6120-01-470-0634

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

6 Dec 1999

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6120-01-470-0634 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZS011 Dec 1999
ZH011 Mar 2002
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6120-01-470-0634 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD73-190-0223  08742   CAGE/08742
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6120-01-470-0634 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 Dec 1999
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Dec 1999

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6120-01-470-0634 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
50
Code Definitions

50

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Labor-Job Corp, Washington, DC 20213

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6120-01-470-0634 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
AYNHOperating Ambient Temp Range-10.0/+50.0 DEG CELSIUS
CWHFOutput Connection Quantity6 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
CWHJOutput Connection TypeTHREADED STUD MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
CWHCOutput Control LocationFRONT PANEL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
BGHXOutput Control Quantity6 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
BGHYOutput Control TypeVOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
CWGHOutput Current Rating5.0 DC AMPERES NOMINAL 4TH POWER OUTPUT
CWGHOutput Current Rating5.0 DC AMPERES NOMINAL 5TH POWER OUTPUT
CWGHOutput Current Rating5.0 DC AMPERES NOMINAL 6TH POWER OUTPUT
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating10.0 DC AMPERES NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating21.4 DC AMPERES NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating28.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APPAOutput Voltage Rating5.0 DC VOLTS NOMINAL 6TH POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating12.0 DC VOLTS NOMINAL 5TH POWER OUTPUT
APPAOutput Voltage Rating15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
BGQROutput Wattage Rating250.0 WATTS NOMINAL 2ND POWER OUTPUT
BGQROutput Wattage Rating250.0 WATTS NOMINAL 3RD POWER OUTPUT
BGQROutput Wattage Rating250.0 WATTS NOMINAL 4TH POWER OUTPUT
BGQROutput Wattage Rating250.0 WATTS NOMINAL 5TH POWER OUTPUT
BGQROutput Wattage Rating250.0 WATTS NOMINAL 6TH POWER OUTPUT
BGQROutput Wattage Rating600.0 WATTS NOMINAL 1ST POWER OUTPUT
APTQInput Frequency Rating47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT AND THREE SINGLE OPERATING POWER RQMT
APNXInput Voltage Rating85.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT
ABKWOverall Height5.000 INCHES NOMINAL
ABHPOverall Length12.210 INCHES NOMINAL
ABMKOverall Width7.900 INCHES NOMINAL
CWKGVentilation Design TypeEXTERNAL BLOWER


Back to Top
Back to Top