6125-00-251-6303

MOTOR-GENERATOR


6125-00-251-6303 (6125002516303, 002516303)
Part Number (1 listing): 17M70322-6950
Summary

FSG 61 / FSC 6125

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6125-00-251-6303 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
17M70322-69503 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6125-00-251-6303 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
616125002516303A271A000830X49ANA01 Jan 1963
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6125

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Converters, Electrical, Rotating

002516303

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6125-00-251-6303

A271A0

Federal Item Identification Guide (FIIG_4065)

00830

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6125-00-251-6303 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Jul 1997
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6125-00-251-6303 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX07 Nov 1981
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Nov 1981

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6125-00-251-6303 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q593Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

593

Water Commodity Code (WRT_CMDTY_CD_9275)


Motors and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 6125-00-251-6303 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9GYU1EA0
Code Definitions

S9G

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Aviation, Richmond, VA 23297 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6125-00-251-6303 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAJUOverall Length25.500 INCHES
AAJVOverall Width13.375 INCHES
AAJTOverall Height14.375 INCHES
AXGYMounting MethodBED PLATE
AXHRMounting Facility Type And Quantity4 UNTHREADED HOLE
CWDTNominal Center To Center Distance Between Mounting Facilities Parallel To Length9.000 INCHES
CWFYNominal Center To Center Distance Between Mounting Facilities Parallel To Width9.250 INCHES
ANPZInclosure FeatureWEATHERPROOF
BKPQInclosure SpecificationMIL-STD-108
ACDCCurrent TypeAC INPUT
ACDCCurrent TypeDC OUTPUT
FREQFrequency In Hertz60.0 INPUT
FAAZPhaseTHREE INPUT
CWGQConnection Type And Voltage Rating In Volts440.0 LINE TO NEUTRAL SINGLE INPUT
CWGQConnection Type And Voltage Rating In Volts250.0 LINE TO NEUTRAL SINGLE OUTPUT
AKPSDuty CycleCONTINUOUS
CWDYTemp Rating70.0 AMBIENT DEG CELSIUS
BFMFCooling MethodAMBIENT AIR
CWFXRotor Speed Rating In Rpm3450.0 SINGLE FULL LOAD
CBBLFeatures ProvidedHORIZONTAL MOUNTING POSITION


Back to Top
Back to Top