Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4R0513 | 3 - Design Control Reference | 9 - No Longer Used | BAXTER HEALTHCARE CORPORATION | 02606 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 6515 | 000799483 | T107-M | 20915 | X | 1 | A | N | A | 5 Apr 1972 |
Medical, Dental, and Veterinary Equipment and Supplies
Medical and Surgical Instruments, Equipment, and Supplies
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 4 | KX | D | 4R0513 | 02606 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 98 | 0 | 1 Feb 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KX | F | 651 | Z | 9 | A | M | Z | F | 056680 | X | 32570 | DENTAL-MEDICAL-SURG-INST-R-MACHINE | 1 |
Defense Supply Center Philadelphia, Philiadelphia, PA 19101
150
Instruments, Medical and Surgical
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Medical supplies, equipment, samples records, etc.
No special handling required.
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
DLA Troop Support, Director of Medical Material, Philadelphia, PA 19145 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
8
Can - A rigid receptacle made of fibre, metal, plastic or a combination thereof. Cans may be cylindrical or any number of irregular shapes. Restricted to items which cannot be issued in less than container quantity. Includes “pail” and “canister”. Do not use when the packaged quantity equates to a unit of measure, i.e., pint, quart, gallon, ounce or pound. *Requires a quantitive expression
TYPE I (48 Months (4.00-Years) ) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CBFG | Bag Material | PLASTIC |
CKYS | Bag Capacity | 450.0 MILLILITERS |
AWDT | Transparent Feature | INCLUDED |
CMNC | Anticoagulant Solution | PROVIDED |
CMND | Anticoagulant Solution Capacity | 63.0 MILLILITERS |
AJKD | Nonsupply Items And Quantities | BALL CHECK,1; NEEDLE,15 OR 16 GAGE,1; SHEATH,1; TUBING,PLASTIC,1 |
CMNF | Donor Set Type | INTEGRAL |