LO-9-2350-266-12

CARRIER, PERSONNEL, FULL TRACKED, ARMORED FIRE SUPPORT, M981

LUBRICATION ORDER

MARCH 1990

  LO-9-2350-266-12 - Page 1 of 48

LUBRICATION ORDER
LO 9-2350-266-12
19 March 1990
Supersedes LO 9-2350-266-12,
dated 10 April 85.
CARRIER, PERSONNEL, FULL TRACKED,
ARMORED FIRE SUPPORT,
M981 (NSN 2350-01-085-3792)
References: TM 9-2350-266-10, TM 9-2350-266-20, TM 9-2350-261-20, TB 43-0210, and CL9100SL
Intervals (on-condition or hard time) and the
related man-hour times are based on normal
operation. The man-hour time specified is the
time you need to do all the services pre-
scribed for a particular interval. Hard time
intervals will be indicated by one of the
following symbols as appropriate: Daily (D),
Weekly (W), Monthly (M), Semiannually (S),
and Annually (A). On-Condition (OC) oil sam-
ple intervals shall be applied unless changed
by the Army Oil Analysis Program (AOAP)
laboratory. Change the hard time interval if
your lubricants are contaminated or if you are
operating the equipment under adverse oper-
ating conditions, including longer-than-usual
operating hours. The hard time interval may
be extended during periods of low activity. If
extended, adequate preservation precautions
must be taken. Hard time intervals will be
applied in the event AOAP laboratory sup-
port is not available. Clean fittings before
lubricating. Clean parts with dry cleaning
solvent P-D-680. Dry before lubricating. Dot-
ted arrow points indicate lubrication on both
sides of the equipment.
LEVEL OF MAINTENANCE.
The lowest
level of maintenance authorized to lubricate a
point is indicated by one of the following
symbols as appropriate: Operator/Crew (C)
and Unit Maintenance (O).
REPORTING ERRORS AND RECOMMENDING
IMPROVEMENTS.
You can help improve
this manual. If you find any mistakes or if you
know of a way to improve the procedures,
please let us know. Mail your letter or DA
Form 2028 (Recommended Changes to Pub-
hcations and Blank forms) direct to: Com-
mander, US Army Tank-Automotive Com-
mand, ATTN: AMSTA-MB, Warren, Ml
48397-5000. A reply will be furnished to
you.
WARNIN G
Dry cleaning solvent is toxic and
flammable. Death or injury may
result. To avoid death or injury,
do the following:
Wear protective goggles and
gloves and use only in well
ventilated area. Avoid breathing
vapors.
Avoid using near open flame or
excessive heat (flash point is
100-138°F or 38-50°C).
If you become dizzy while using
solvent, get fresh air immediate-
ly and get medical aid.
If contact with eyes is made,
wash your eyes with water and
get medical aid immediately.
NOTE
Park carrier on level ground to
check oil levels. Check/lubricate
all oil and grease fitting points
after washing or fording.
ARMY OIL ANALYSIS PROGRAM (AOAP).
AOAP is an effective maintenance diagnostic
tool and not a maintenance substitute. TB
43-0210 must not be interpreted to mean
AOAP minimizes, in any way, the need to
employ good maintenance practices and
strong maintenance disciplines.
Approved for public release; distribution is unlimited.
Card 1 of 51/(52 blank)