TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 127 of 528

TM 9-2330-356-14
Table 3-2. Operator/Crew Troubleshooting (Con‘t).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE
10. ENGINE WILL NOT TURN OVER.
Step 1.
Remove battery cover and check for loose battery cable connections (para 3-6).
Tighten loose connections.
Step 2.
Check for discharged or defective battery.
a.
Remove cell caps and check for loss of electrolyte. Fill each cell as necessary
(para 3-6).
NOTE
Do
not slave start or jump start batteries.
b.
If battery is discharged, notify unit maintenance.
11. ENGINE HARD TO START OR TURNS OVER SLOWLY.
Step 1.
Step 2.
Step 3.
Remove battery cover and check for discharged or defective battery.
a.
Remove cell caps and check for loss of electrolyte, Fill each cell as necessary
(para 3-6).
NOT E
Do not slave start or jump start batteries.
b.
If battery is discharged, notify unit maintenance.
Check air cleaner dirt indicator for showing of red band.
If red band is showing, service air cleaner (para 3-1 8).
Check for fuel line leaks.
If connections are loose or lines are damaged, notify unit maintenance.
12. ENGINE TURNS OVER BUT FAILS TO START
Check level of fuel in fuel tank.
Add fuel.
3-31


Back to Top