TM 9-2330-356-14
4-15.
Composite Tall Stop Lights
WARNING
TA099780
Figure 4-24. Exploded View of Marker Light.
When troubleshooting an electrical malfunc-
tion or performing electrical maintenance,
ALWAYS disconnect intervehicular electrical
cable from semitrailer, and negative battery
cables at batteries. Failure to follow this warn-
ing may create a spark and explosion, result-
ing in serious injury or death to personnel.
a.
Lamp or Lens Replacement.
(1) Loosen six captive screws (fig. 4-25) which
fasten door and lens to body.
(2) Remove door and lens find preformed pack-
ing.
(3) Remove defective lamp and install a new
lamp.
(4) Inspect preformed packing and replace if
damaged.
(5) Inspect door and lens assembly. If damaged,
replace. Secure door and lens assembly to body assembly
with six screws.
b.
Removal.
(1) Loosen six self-tapping screws (fig. 4-23) that
fasten cover plate to semitrailer. Remove cover plate and
gasket.
(2) Disconnect light wires from harness.
(3) Remove the two capscrews and Iockwashers
(fig. 4-25) that attach composite light to plate.
(4) Remove composite light and gasket.
c.
Installation.
(1) Fasten composite light and gasket to cover
plate with two lockwashers and capscrews (fig. 4-25).
(2) Connect light wires to the harness.
(3) Install cover plate and secure with six
self-tapping screws.
4-44