4-17. Circuit Breaker
WARNING
When troubleshooting an electrical malfunc-
tion or performing electrical maintenance,
ALWAYS disconnect intervehicular electrical
cable from semitrailer, and negative battery
cables at batteries. Failure to follow this warn-
ing may create a spark and explosion, result-
ing in serious injury or death to personnel.
a.
Removal.
(1) Disconnect negative battery cable from
battery (fig. 4-37).
(2) Loosen engine junction box clamp screws and
open cover.
(3) Disconnect all leads from preheater solenoid
and circuit breaker (fig. 4-30).
(4) Disconnect lead No. 54 (fig. 4-30) that goes
to fuel pumps from terminal strip.
(5) Loosen three cable connectors (fig. 4-30) on
side of junction box.
(6) Pull the two large leads through the
connectors until they are almost removed from the
junction box.
(7) Remove four screws (6, fig. 4-31) and
washers (7) that secure mounting plate to control panel.
(8) Tilt mounting plate (8) for access to circuit
breaker mounting screws (13).
(9) Remove the two screws (13) and circuit
breaker (12).
b.
Installation.
(1) Install circuit breaker to plate with two screws
(13, fig. 4-31).
(2) Fasten mounting plate to control panel with
four screws (6) and washers (7). Ground lead is to be
installed with upper left screw.
TA502346
Figure 4-30. Location of Circuit Breaker and Preheater Solenoid in Junction Box.
4-50