1430-00-948-5055

CABLE ASSEMBLY,POWER,ELECTRICAL


1430-00-948-5055 (1430009485055, 009485055)
Part Number (1 listing): 19-1015775-1
Summary

FSG 14 / FSC 1430

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Apr 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 1430-00-948-5055 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
19-1015775-13 - Design Control Reference2 - Production ItemGENERAL DYNAMICS C4 SYSTEMS, INC.  04655    CAGE 04655  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 1430-00-948-5055 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
141430009485055A077A000485XM9ANA1 Apr 1966
Code Definitions

14

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Guided Missiles

1430

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Guided Missile Remote Control Systems

009485055

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 1430-00-948-5055

A077A0

Federal Item Identification Guide (FIIG_4065)

00485

Item Naming Code (INC_4080)

1 Apr 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 1430-00-948-5055 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
WN011 Feb 2001
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 1430-00-948-5055 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3322SUD19-1015775-1  04655   CAGE/04655
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SU

Reference Number Action Activity Code (RNAAC_2900)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 1430-00-948-5055 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6BD011 Dec 1968
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

BD

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Dec 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 1430-00-948-5055 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SUQ743ZZAHZW061130Z34350CABLE-ASSEMBLY-OR-HARNESS-ELEC--NOI1
Code Definitions

SU

Originating Activity Code (ORIG_ACTY_CD_4210)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

Q

Less Than Carload (LCL_CD_2760)


70

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY-OR-HARNESS-ELEC--NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 1430-00-948-5055 Submit RFQ
MRCDecoded RequirementClear Text Reply
AWTBAccessory Wire Type And Quantity1 GROUND
CXCWConductor FormSTRANDED ALL CONDUCTORS
CXFGConductor Sequence Within GroupsFIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP
CXFGConductor Sequence Within GroupsTHIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP
CXDQConductor Arrangement And Quantity4 TWISTED PAIR
AAGRCross-Sectional Shape StyleROUND
ZZZVFsc Application DataANTENNA-RECEIVER-TRANSMITTER GROUP,MISSILE TRACKING
AMQNConductor Quantity8
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC POLYAMIDE 1ST POSITION JACKET FIRST GROUP
MATTMaterialPLASTIC POLYAMIDE 2ND POSITION JACKET SECOND GROUP
MATTMaterialPLASTIC POLYAMIDE 3RD POSITION JACKET THIRD GROUP
MATTMaterialPLASTIC POLYAMIDE 4TH POSITION JACKET FOURTH GROUP
CXDCRound Conductor Size16 AWG ALL CONDUCTORS
AAJUOverall Length183.000 FEET
CXFKVoltage Rating600.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CXDGStrand Awg Size Per Conductor29 ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
STYLStyle DesignatorEXTERNAL ANGLE CONNECTOR AND LUG
SFTTSurface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code11293 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code11293 2ND END ALL CONDUCTORS
CXFMTerminal Lug Aperture Size0.147 INCHES 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number73-200901-11 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number73-266259-1300 1ST END ALL CONDUCTORS


Back to Top
Back to Top