1440-00-001-2476

SPRING ASSEMBLY,SHOCK ISOLATOR


1440-00-001-2476 (1440000012476, 000012476)
Part Numbers (2 listings): 25-66608-2 | 25-66608-5 |
Summary

FSG 14 / FSC 1440

DEMIL: F

DEMIL INT: 1

HMIC: N

Date Created: 18 Sep 1972

Unit Weight: 1,051.0 lbs

Unit Size: 6ft 4in x 24in x 24.8in

Unit Pack Cube: 26.177 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 1440-00-001-2476 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
25-66608-23 - Design Control Reference2 - Production ItemTHE BOEING COMPANY  81205    CAGE 81205  
25-66608-55 - Replaced / Discontinued2 - Production ItemTHE BOEING COMPANY  81205    CAGE 81205  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 1440-00-001-2476 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
141440000012476A2390077777XM1FNAA018 Sep 1972
Code Definitions

14

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Guided Missiles

1440

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Launchers, Guided Missile

000012476

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 1440-00-001-2476

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

18 Sep 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

F

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Demilitarization instructions to be furnished by the Item/Technical Manager.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 1440-00-001-2476 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU400FESUFH1 Apr 1991
WN011 Jul 2013
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

SU

Item Management Coding Activity (IMC_ACTY_2748)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 1440-00-001-2476 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3322SUD25-66608-2  81205   CAGE/81205
4526SBD25-66608-5  81205   CAGE/81205
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SU

Reference Number Action Activity Code (RNAAC_2900)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 1440-00-001-2476 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TU09 May 1974
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

9 May 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 1440-00-001-2476 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SUQ579ZZZAZQ177820B87380SPRING-ASSEMBLIES-STL-O-T-WIRE-SUB21
Code Definitions

SU

Originating Activity Code (ORIG_ACTY_CD_4210)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

Q

Less Than Carload (LCL_CD_2760)


70

579

Water Commodity Code (WRT_CMDTY_CD_9275)


Steel Springs, (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

Z

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.

A

Air Commodity Code (AIR_CMTY_HDLG_9215)


Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

177820

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

B

NMFC Sub Item Number (SUB_ITM_NBR_0861)

87380

Uniform Freight Classification (UFC_CD_MODF_3040)

SPRING-ASSEMBLIES-STL-O-T-WIRE-SUB2

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 1440-00-001-2476 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZC71TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG W - PACKAGING DATA | NSN 1440-00-001-2476 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP2010001,051.0 lbs6ft 4in x 24in x 24.8in26.177 cu ft850.0 lbs5ft 9in x 12in x 12in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
02ZZZZZZZ00BZZA
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

20

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preservative coating only (with greaseproof wrap, as required)

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

1,051.0 lbs

Unit Pack Weight (UP_WT_5153)

6ft 4in x 24in x 24.8in

Unit Pack Size (UP_SZ_5154)

26.177 cu ft

Unit Pack Cube (UP_CU_5155)

850.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

5ft 9in x 12in x 12in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

02

Preservation Material Code (PRSRV_MAT_CD_5162)


MIL-PRF-16173, Grade 2, corrosion preventive, solvent cutback, cold application, soft film

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 1440-00-001-2476 Submit RFQ
MRCDecoded RequirementClear Text Reply
TEXTGeneral Characteristics Item DescriptionASSEMBLY OF 1 LIQUID SPRING,PRESSURE MONITOR,SPRING TO BE PRESSURIZEDTO 20000 PSIG WHILE SUPPORTING WEIGHT OF 41000 LBS
ZZZVFsc Application DataMISSILE SYSTEM LGM-30


Back to Top
Back to Top