1650-00-307-6060

DRIVE UNIT,HYDRAULIC


1650-00-307-6060 (1650003076060, 003076060)
Part Numbers (2 listings): 1639E1E | 1639E1 |
Summary

FSG 16 / FSC 1650

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: 30.1 lbs

Unit Size: 20.5in x 16.5in x 16.5in

Unit Pack Cube: 3.229 cu ft

Replacement NSN:

1650-00-566-2693

Replacement Date: 3 Apr 1982

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 1650-00-307-6060 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1639E1E3 - Design Control Reference2 - Production ItemTRIUMPH GEAR SYSTEMS, INC.  82402    CAGE 82402  
1639E1E3 - Design Control Reference2 - Production ItemTRIUMPH GEAR SYSTEMS, INC.  82402    CAGE 82402  
1639E1E3 - Design Control Reference2 - Production ItemCONTROL FLOW, INC.  3X894      
1639E1E3 - Design Control Reference2 - Production ItemCONTROL FLOW, INC.  3X894      
1639E1E5 - Replaced / Discontinued9 - No Longer UsedCONTROL FLOW, INC.  16603    CAGE 16603  
1639E15 - Replaced / Discontinued9 - No Longer UsedTRIUMPH GEAR SYSTEMS, INC.  82402    CAGE 82402  
1639E15 - Replaced / Discontinued9 - No Longer UsedTRIUMPH GEAR SYSTEMS, INC.  82402    CAGE 82402  
1639E1E5 - Replaced / Discontinued9 - No Longer UsedCONTROL FLOW, INC.  16603    CAGE 16603  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 1650-00-307-6060 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
161650003076060A572U061630X43BNA01 Jan 1963
Code Definitions

16

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Aerospace Craft Components and Accessories

1650

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Aircraft Hydraulic, Vacuum, and De-icing System Components

003076060

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 1650-00-307-6060

A572U0

Federal Item Identification Guide (FIIG_4065)

61630

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG C - REFERENCE NUMBER | NSN 1650-00-307-6060 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
322ZZ1639E1E  3X894  
3322SXD1639E1E  82402   CAGE/82402
3592SXB1639E1E  16603   CAGE/16603
3592SBB1639E1  82402   CAGE/82402
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

SX

Reference Number Action Activity Code (RNAAC_2900)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 1650-00-307-6060 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3GP61GP03 Apr 1982 1650005662693 24 Mar 1982
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

GP

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Naval Inventory Control Point, Philadelphia, PA 19111-5098

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Apr 1982

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

1650-00-566-2693

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

24 Mar 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 1650-00-307-6060 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 1650-00-307-6060 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP41100030.1 lbs20.5in x 16.5in x 16.5in3.229 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XED00B00O
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

30.1 lbs

Unit Pack Weight (UP_WT_5153)

20.5in x 16.5in x 16.5in

Unit Pack Size (UP_SZ_5154)

3.229 cu ft

Unit Pack Cube (UP_CU_5155)

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ED

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 1650-00-307-6060 Submit RFQ
MRCDecoded RequirementClear Text Reply
FEATSpecial FeaturesMEDIA HYD FLUID


Back to Top
Back to Top