Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
89H1070-10 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
89H1070-9 | 5 - Replaced / Discontinued | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 1650 | 006011288 | A34200 | 31310 | N | M | 9 | B | N | A | 0 | 1 Jan 1963 |
Aircraft Hydraulic, Vacuum, and De-icing System Components
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N2R4 | 3 | H | V | E | KE | GG | 1 Apr 1991 | |||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YY01 | 1 Feb 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
An activity within the Navy is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Naval ICP, Philadelphia, PA 19111
Naval Inventory Control Point, Philadelphia, PA 19111û5098
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | GP | 0 | 3 | GP | 1 | 9 Oct 1975 | 1650000281197 | 2 Sep 1976 |
1 | GP | 0 | 3 | GP | 1 | 9 Oct 1975 | 1650000982160 | 2 Sep 1976 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Naval Inventory Control Point, Philadelphia, PA 19111-5098
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | 9 | A | V | Z | Q | 119260 | X | 60780 | CYLINDERS-HYDRAULIC-PNEUMATIC |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
70
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Unclassified
No QUP
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
X | P | A | DR | 1 | 000 | 2.5 lbs | 10in x 6in x 4in | 0.174 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
65 | GB | GH | B | EC | 00 | O | 00 | E | Q | M |
Validated Correction
Primary Inventory Control Activity (PICA)
Heated General Purpose – Heated 40 F and above
Preserve by Method 30 as follows: Each unit shall have all internal fluid-carrying passages, which are not prelubricated, filled with the specified preservative, allowing space for internal thermal expansion. If filling is not practical, the unit shall be internally fog-sprayed or flushed, then drained to the drip point. All ports, fittings, openings, etc., shall be capped or plugged with noncorrosive (noninteracting) metal caps or plugs conforming to NAS 847 or equivalent. All hydraulic preservative operating fluid used shall be filtered through a 3 micron absolute filter prior to being used as specified above. Exterior bare metal surfaces, subject to corrosion, shall be coated with compound conforming to MIL-PRF16173, Grade 2 or MIL-C-11796, Class 3. Unit shall be wrapped with a greaseproof wrap conforming to MIL-PRF-121 or equivalent; seal seams with ASTM-D5486 tape to effect a measure of waterproofness and prevent unwrapping. The unit must be adequately cushioned with material specified and placed in a grade V3c container fabricated in accordance with ASTM-D5118 (as a minimum), Style FOL or CSSC. All seams, corners, and manufacturer's joint shall be tape-sealed with two inch tape conforming to ASTM-D5486, Type III or IV.
Any suitable process that is not injurious to the item.
MIL-PRF-83282, hydraulic fluid, synthetic, fire retardant
MIL-PRF-121, greaseproof, waterproof barrier
MIL-PRF-26514, Type I, Class 2, Grade C, flexible polyurethane foam, heavy load range
1/2 inch thick
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
No requirement.
Unit container is not an acceptable shipping container.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAFZ | Body Material | STEEL |
ABXV | Bore Diameter | 1.000 INCHES NOMINAL |
AMQZ | Compressed Length | 6.516 INCHES NOMINAL |
CKSD | Design Characteristics | SINGLE ACTING SINGLE CYLINDER |
ATEM | Extended Length | 7.625 INCHES NOMINAL |
ZZZV | Fsc Application Data | HYDRAULIC SYSTEMS,ACFT |
CLMS | Port Location And Quantity | 1 CENTER SECTION |
CLMT | Port Style | GASKET SEAL |
CLNB | Port Thread Class | 3B |
CLMX | Port Thread Diameter | 0.438 INCHES NOMINAL |
CLMY | Port Thread Quantity Per Inch | 20 |
CLMW | Port Thread Series Designator | UNF |
BGST | Pressure Rating | 3000.0 POUNDS PER SQUARE INCH NOMINAL |
AJFY | Seat Angle In Deg | 60.0 |
ABKW | Overall Height | 2.000 INCHES NOMINAL |
ABMK | Overall Width | 1.500 INCHES NOMINAL |
FEAT | Special Features | WITH PISTON SPRING LOADED TOWARD EXTENDED POSITION; EXTERNAL STRIKER BUTTON TO RELEASE BALL LOCK ASSEMBLIES |