| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 37D401329G024 | 3 - Design Control Reference | 2 - Production Item | GENERAL ELECTRIC COMPANY | 99207 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 28 | 2840 | 012812772 | A10700 | 50591 | F | M | 3 | D | N | A | 21 Jun 1988 |
Gas Turbines and Jet Engines, Aircraft, Prime Moving; and Components
The item is an Aviation Critical Safety Item/Flight Safety Critical Aircraft Part ((ACSI/FSCAP).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | 1 Feb 1994 | |||||||||||||||||||||||||||||
| FXX4 | FEE4 | 3 | D | F | E | FT | 1 May 2001 | |||||||||||||||||||||||
| NAXS | NAES | 3 | D | 4 | E | JA | GG | 1 May 2001 | ||||||||||||||||||||||
| ZH01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
| ZU01 | 1 May 2008 | |||||||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.
An activity within the Air Force is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Depot Reparable Component. (Type I Temporary). This code identifies SICA managed depot reparable components assigned to another service PICA that is responsible for the logistics functions of single submitter of cataloging data, acquisition and disposal authority and depot maintenance to be provided by DMISA. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by the PICA. The SICA is responsible for the wholesale stock, store and issue functions for SICA activities. This code is temporarily assigned to items which have not completed Phase II item review processing. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Oklahoma City Air Logistics Center (OC-ALC), Tinker AFB, OK
Fleet Readiness Center South East (FRC-SE), Jacksonville FL
Naval Inventory Control Point, Philadelphia, PA 19111û5098
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 1 | TU | 0 | 3 | TU | 0 | 27 Jun 2000 | 2840004560447 | 27 Jun 2000 |
| 1 | TU | 0 | 3 | TU | 0 | 27 Jun 2000 | 2840010053050 | 27 Jun 2000 |
| 1 | TU | 0 | 3 | TU | 0 | 27 Jun 2000 | 2840012242200 | 27 Jun 2000 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SE | 671 | Z | 9 | A | A | Z | W | 114215 | Z | 63220 | ASSEMBLIES-JET-AIRCRAFT-ENGINE |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Aircraft Parts, To include Test/Tool Sets and Equipment (other than armament systems)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft instruments and laboratory test equipment, aerial targets and gliders, aircraft/missile technical order compliance kits, etc
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
1
NAVY: (1) Iram program intensive management reparables (2) material (expendable ordnance) requiring lot and serial-# control but which is reported by serial-# only.
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Department of the Navy
Department of the Air Force
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | S | A | DW | 1 | 000 | 24.5in x 23in x 17.5in | 5.700 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| K3 | BG | X | RC | 00 | A | 03 | F | F | F | M |
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | ZZ | Z | 000 | 40.0 lbs | 19.4in x 19.4in x 9.3in | 2.025 cu ft | 30.0 lbs | 17in x 17in x 7in |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ZZ | ZZ | ZZ | Z | ZZ | 00 | B | ZZ | A |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Secondary Inventory Control Activity (SICA)
Heated General Purpose – Heated 40 F and above
Preserve by Method 52 as follows: Item shall be cleaned, wrapped, blocked and braced in an interior carton fabricated in accordance with ASTM-D5118, Class domestic. MIL-PRF-131 barrier material, sealed as required, shall be utilized around the first container. The cushioning, to be specified under the cushioning code and in the thickness required to adequately protect the item, shall be placed between the barrier and the outer container.
Any suitable process that is not injurious to the item.
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or MIL-DTL-117, Type II, Class H, Style 2 bag
A-A-1898, Grade II, water resistant cellulosic cushioning
As required to protect the item or elements of the package
NAVICP Drawing No. 15450, modular reusable container for packaging depot level repairables.
No requirement.
Unit container provides level A packing protection.
Mehod 50
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing is not required; the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
No requirement.
Unit container provides level B packing protection.
Special requirements
Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AGAV | End Item Identification | ACGT ENG J85-GE-5J/-13D/-17A |
| CRTL | Criticality Code Justification | AGAV AND FEAT |
| RDAL | Reference Data And Literature | T.O 2J-J85-64 |
| FEAT | Special Features | FSCAP |