Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
6266604 | 3 - Design Control Reference | 2 - Production Item | U S ARMY TANK AUTOMOTIVE COMMAND | 19207 | ![]() |
905850 | 5 - Replaced / Discontinued | 9 - No Longer Used | SASCO INC CANADIAN DIV | 58275 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
29 | 2920 | 000348722 | T130-H | 17084 | X | K | A | N | U | 1 Jan 1963 |
Engine Electrical System Components, Nonaircraft
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | AX | 0 | 30 Mar 1975 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWZB | Closing Voltage Rating | 7.0 VOLTS MINIMUM AND 9.0 VOLTS MAXIMUM |
AXCC | Contact Manual Closing Provision | NOT INCLUDED |
AXCD | Control Terminal Quantity | 2 |
AXCE | Control Terminal Type | SCREW |
AXBE | Engaging Linkage | INCLUDED |
AXCF | Grounded Control Terminal | INCLUDED |
AXBA | Hold-In Current | 2.1 AMPERES MINIMUM AND 2.5 AMPERES MAXIMUM |
AXHN | Motor Diameter For Which Rigid Mount Is Designed | 4.438 INCHES NOMINAL |
ARKQ | Mounting Facility Spacing | 1.747 IN. MIN 1.753 IN. MAX C TO C |
AXHR | Mounting Facility Type And Quantity | 4 SLOT |
ABVG | Mounting Slot Length | 0.344 INCHES NOMINAL |
ABTD | Mounting Slot Width | 0.281 INCHES NOMINAL |
AWYG | Nominal Voltage Rating | 12.0 VOLTS |
AXAY | Opening Voltage Rating | 3.0 VOLTS MINIMUM AND 5.0 VOLTS MAXIMUM |
AXBG | Linkage Adjustability | ADJUSTABLE |
AXBH | Linkage Shift Lever Connection Type | THREADED ROD |
AXHJ | Main Terminal Quantity | 2 |
AXHK | Main Terminal Type | STUD |
AXAZ | Pull-In Current | 16.700 AMPERES MINIMUM AND 19.500 AMPERES MAXIMUM |
AXBD | Plunger Stroke Length | 0.500 INCHES NOMINAL |
AHZV | Submersibility | NONSUBMERSIBLE |