Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
374866R91 | 3 - Design Control Reference | 9 - No Longer Used | INTERNATIONAL HARVESTER CO | 29930 | ![]() |
374866R91 | 5 - Replaced / Discontinued | 9 - No Longer Used | NAVISTAR INTL CORP | 31007 | ![]() |
XHD-2656 | 5 - Replaced / Discontinued | 9 - No Longer Used | WICO-PRESTOLITE CO THE DIV OF ELTRA | 79575 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
29 | 2920 | 008676580 | A12200 | 00113 | X | 1 | A | N | A | 1 Jan 1960 |
Engine Electrical System Components, Nonaircraft
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Feb 1994 | |||||||||||||||||||||||||||||
ZH01 | 1 Aug 1995 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 5 | AX | D | 374866R91 | 29930 | ![]() | ||||
3 | 5 | 9 | 5 | AX | B | 374866R91 | 31007 | ![]() | ||||
4 | 5 | 9 | 5 | AX | B | XHD-2656 | 79575 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | AX | 0 | 3 | AX | 1 | 7 Nov 1967 | 2920001965444 | 1 Feb 1973 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 658 | M | 9 | A | H | Z | M | 062460 | X | 34940 | MAGNETOS-PARTS-NOI-IN-BOXES-CRATES |
85
Electical Appliances, Small
Magnetic material
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43215 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
* Special Requirements
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 52 | 1 | 000 |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 10 | 00 | 00 | Q | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
As required to protect the item or elements of the package
Any suitable container included in this table may be used (see J.4.9.1).
No requirement.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ARFE | Distributor Cap | INCLUDED |
AAYX | Drive Connection Type | IMPULSE COUPLED |
AJAB | Drive Shaft Type | THREADED |
AAFZ | Body Material | ALUMINUM ALLOY |
AYKN | Contact Set Quantity | 1 |
AEJN | Distance Between Mounting Facility Centers | 4.200 INCHES NOMINAL |
AXRW | Ignition Type For Which Designed | SINGLE |
AYKF | Maximum Advance Deg | 20.0 |
AZGM | Mounting Facility | SLOT AND THREADED HOLE |
AKPV | Mounting Facility Quantity | 1 |
CPWR | Mounting Facility Thread Diameter | 0.375 INCHES NOMINAL |
CPWN | Mounting Facility Thread Series | UNC |
CPWS | Mounting Facility Thread Quantity Per Inch | 16 |
ABTD | Mounting Slot Width | 0.430 INCHES NOMINAL |
AYFE | Mounting Standard Number | J546 |
AYFB | Mounting Standard Controlling Agency | SAE |
AXGY | Mounting Method | FLANGE |
ABVG | Mounting Slot Length | 1.125 INCHES NOMINAL |
AXRT | Impulse Quantity Per Revolution | 2 |
AKPX | Pole Quantity | 2 |
AYKH | Rotation Element Type | PERMANENT MAGNET ROTOR |
AYEN | Secondary Terminal Type | PUSH-IN |
ABXF | Shaft Length | 0.438 INCHES NOMINAL |
AKCT | Shaft Rotation Direction | COUNTERCLOCKWISE |
AYKD | Spark Advance Control Method | MANUAL |
CPWB | Spark Distribution Method | GAP |
AGLD | Performance Type | HIGH TENSION |
FEAT | Special Features | BLACK ENAMEL |
SFTT | Surface Treatment | ENAMEL |