Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
112504 | 3 - Design Control Reference | 2 - Production Item | PARKER-HANNIFIN CORPORATION | 93835 | |
517D296P3 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL ELECTRIC COMPANY | 99207 | |
1125-0-4 | 5 - Replaced / Discontinued | 2 - Production Item | PARKER-HANNIFIN CORPORATION | 93835 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
29 | 2995 | 005601377 | A34200 | 31310 | X | M | 4 | A | N | A | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 5 | 2 | 1 | SX | D | 517D296P3 | 99207 | |||||
3 | 5 | 2 | 1 | SX | D | 1125-0-4 | 93835 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TU | 0 | 3 | TU | 1 | 8 Apr 1970 | 2995009573701 | 20 Feb 1970 |
1 | TU | 0 | 3 | TU | 1 | 8 Apr 1970 | 3040008758933 | 20 Feb 1970 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAR | Body Outside Diameter | 2.090 INCHES MINIMUM AND 2.100 INCHES MAXIMUM |
AMQZ | Compressed Length | 20.075 INCHES NOMINAL |
CKSD | Design Characteristics | DOUBLE ACTING SINGLE CYLINDER |
ATEM | Extended Length | 26.640 INCHES NOMINAL |
AMEA | First End External Thread Length | 3.250 INCHES NOMINAL |
AAHB | First End Outside Diameter | 0.812 INCHES NOMINAL |
CKSF | First Piston Rod End Style | EXTERNAL THREADED |
CKSK | First Piston Rod End Thread Class | 3A |
CKSH | First Piston Rod End Thread Diameter | 0.812 INCHES NOMINAL |
CKSJ | First Piston Rod End Thread Quantity Per Inch | 20 |
CKSG | First Piston Rod End Thread Series Designator | UNEF |
CLMQ | Mounting Facility Diameter | 0.499 INCHES MINIMUM |
CLMQ | Mounting Facility Diameter | 0.500 INCHES MAXIMUM |
ABDR | Mounting Provision | UNTHREADED MOUNTING HOLES |
CLML | Mounting Type And Location | LUG CYLINDER HEAD END |
CKRM | Integral Valve Operation Method | HYDRAULIC |
BGST | Pressure Rating | 3000.0 POUNDS PER SQUARE INCH NOMINAL |
ADAV | Overall Diameter | 2.650 INCHES NOMINAL |
ABMK | Overall Width | 4.980 INCHES MINIMUM AND 5.020 INCHES MAXIMUM |
ABJH | Temp Rating | -65.0 DEG FAHRENHEIT |
ABJH | Temp Rating | 400.0 DEG FAHRENHEIT |