3010-00-273-1763

COUPLING HALF,SHAFT


3010-00-273-1763 (3010002731763, 002731763)
Part Number (1 listing): 765375
Summary

FSG 30 / FSC 3010

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 3010-00-273-1763 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7653753 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 3010-00-273-1763 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
303010002731763A521X008009X43ANA01 Jan 1963
Code Definitions

30

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Mechanical Power Transmission Equipment

3010

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Torque Converters and Speed Changers

002731763

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 3010-00-273-1763

A521X0

Federal Item Identification Guide (FIIG_4065)

08009

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 3010-00-273-1763 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 3010-00-273-1763 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2AX020 Apr 1976
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

AX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43216-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Apr 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 3010-00-273-1763 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
W593Z9ABZW126880Z64300POWER-TRANS-SHAFTING-PULLEYS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


W

Less Than Carload (LCL_CD_2760)


Rating Variable

593

Water Commodity Code (WRT_CMDTY_CD_9275)


Motors and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

B

Air Commodity Code (AIR_CMTY_HDLG_9215)


Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

126880

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

64300

Uniform Freight Classification (UFC_CD_MODF_3040)

POWER-TRANS-SHAFTING-PULLEYS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 3010-00-273-1763 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9CVU1EA0
Code Definitions

S9C

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43215 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 3010-00-273-1763 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAQLBody Style2 HOLE FLANGE, THROUGH BORE
ABXVBore Diameter0.7500 INCHES MINIMUM AND 0.7510 INCHES MAXIMUM
ADGEBore Length0.6720 INCHES MINIMUM AND 0.7020 INCHES MAXIMUM
AGZDBore ShapeSTRAIGHT
CBBLFeatures ProvidedKEYWAY
MDCLMaterial Document And ClassificationMIL-S-16788, CLASS C2 MIL SPEC SINGLE MATERIAL RESPONSE
MATTMaterialSTEEL
FEATSpecial Features0.250 TO 0.260" DIA. X 77 TO 87 DEG. COUNTERSUNK ON SECURING HOLES; UNTHREADED BORE DIA.:0.323" MON., 0.328" MAX.; POSITIONING FACILITY BOLT CIRCLE DIA.:2.245" MIN., 2.255" MAX.; POSITIONING FACILITY QTY:2; HOLE THREAD SIZE DESIGNATOR:1/4-20 NC-2; POSITIONING HOLE STYLE:PLAIN; THREADED HOLE LOCATION:(1) HOLE LOCATED ON TOP OF KEYWAY,(1) HOLE 180 DEG. FROM KEYWAY 0.340 TO 0.348" FROM FACE END; THREADED HOLE QTY:2; SECURING METHOD:THREADED HOLE; BORE COUNTERBORE FEATURE:NOT INCLUDED; KEYING FACILITY QTY:1; O/A OUTSIDE DIMENSION:2.984" MIN., 3.016" MAX. NOMINAL; HUB OD:1.490" MIN., 1.510" MAX.; THREAD PROVISION:UNTHREADED; DISTANCE FROM CENTER OF BORE TO BOTTOM OF KEYWAY:0.465" NOM.; KEYWAY WD:0.1880" MIN., 0.1890" MAX.; FLANGE THICKNESS:0.245" MIN., 0.250" MAX.
ABHPOverall Length0.672 INCHES MINIMUM AND 0.702 INCHES MAXIMUM


Back to Top
Back to Top