Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
18030-30 | 3 - Design Control Reference | 9 - No Longer Used | ELECTRA MOTORS OPERATION POWER | 95779 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
30 | 3040 | 001165182 | T246-C | 18249 | X | K | A | N | U | 30 Sep 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BC | N9CD | 0 | 0 | Z | GH | HD | 1 Jul 2005 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 1 | AX | D | 18030-30 | 95779 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | AX | 0 | 27 Feb 1973 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AX | 593 | Z | 9 | A | V | Z | M | 129920 | X | 65750 | SHAFTS-SHAFTING-FLEX-NOI-STL |
Defense Supply Center Columbus, Columbus, OH 43216-5000
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAHN | End Similarity | IDENTICAL |
MATT | Material | STEEL,FED STD 66,AISI/SAE 8620 |
CFGM | Involute Spline Length | 0.844 INCHES NOMINAL SECOND END, THIRD PORTION |
CFGL | Involute Spline Pitch Diameter | 1.4000 INCHES NOMINAL SECOND END, THIRD PORTION |
CFGJ | Involute Spline Quantity | 28 SECOND END, THIRD PORTION |
CFGK | Involute Spline Pressure Angle In Deg | 30.0 SECOND END, THIRD PORTION |
CFFM | Shaft Hardness Rating | 60.0 ROCKWELL C MINIMUM AND 62.0 ROCKWELL C MAXIMUM |
CFFW | Shaft Location | BOTH ENDS OF WORM |
ABHP | Overall Length | 11.594 INCHES MINIMUM AND 11.656 INCHES MAXIMUM |
CFFP | Worm Body Length | 7.601 INCHES NOMINAL |
CFFQ | Worm Body Tapered Bearing Surface End | NOT PROVIDED |
CFFG | Worm Helix Angle | 7 DEG 36 MIN |
CFFK | Worm Outside Diameter | 2.533 INCHES NOMINAL |
CFFL | Worm Pitch Diameter | 2.000 INCHES NOMINAL |
CFFF | Worm Pressure Angle In Deg | 25.000 |
CFFD | Worm Thread Direction | RIGHT-HAND |
CFFC | Worm Thread Lead | 0.8378 INCHES NOMINAL |
CFFB | Worm Thread Quantity | 1 |
CFFN | Worm Thread Section Length | 5.500 INCHES NOMINAL |
CFFY | Straight Unthreaded Section Diameter | 1.564 INCHES MINIMUM SECOND END, SECOND PORTION |
CFFY | Straight Unthreaded Section Diameter | 1.565 INCHES MAXIMUM SECOND END, SECOND PORTION |
CFFY | Straight Unthreaded Section Diameter | 1.626 INCHES MINIMUM SECOND END, FIRST PORTION |
CFFY | Straight Unthreaded Section Diameter | 1.627 INCHES MAXIMUM FIRST END, FIRST PORTION |
CFFY | Straight Unthreaded Section Diameter | 1.627 INCHES MAXIMUM SECOND END, FIRST PORTION |
CFFY | Straight Unthreaded Section Diameter | 1.626 INCHES MINIMUM FIRST END, FIRST PORTION |
CFFX | Straight Unthreaded Length | 0.531 INCHES NOMINAL SECOND END, SECOND PORTION |
CFFX | Straight Unthreaded Length | 0.933 INCHES MINIMUM SECOND END, FIRST PORTION |
CFFX | Straight Unthreaded Length | 0.938 INCHES MAXIMUM SECOND END, FIRST PORTION |
CFFX | Straight Unthreaded Length | 1.211 INCHES MINIMUM FIRST END, FIRST PORTION |
CFFX | Straight Unthreaded Length | 1.273 INCHES MAXIMUM FIRST END, FIRST PORTION |
BYFR | Teeth Hardness Rating | 60.0 ROCKWELL C MINIMUM AND 62.0 ROCKWELL C MAXIMUM |