3040-00-455-6365

SHAFT,STRAIGHT


3040-00-455-6365 (3040004556365, 004556365)
Part Number (1 listing): 2838159
Summary

FSG 30 / FSC 3040

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 28 Apr 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 3040-00-455-6365 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
28381593 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 3040-00-455-6365 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
303040004556365A2320022109XKANA028 Apr 1969
Code Definitions

30

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Mechanical Power Transmission Equipment

3040

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Power Transmission Equipment

004556365

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 3040-00-455-6365

A23200

Federal Item Identification Guide (FIIG_4065)

22109

Item Naming Code (INC_4080)

28 Apr 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 3040-00-455-6365 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE011 Apr 1991
YY011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 3040-00-455-6365 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321HDD2838159  10001  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 3040-00-455-6365 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 3040-00-455-6365 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HD
Code Definitions

HD

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 3040-00-455-6365 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAHNEnd SimilarityIDENTICAL
AMESFirst End Distance Between Keyway Centers20.629 INCHES NOMINAL
AMDHFirst End Distance From Keyway Center To End0.4200 INCHES NOMINAL
AMDEFirst End External Keyway Length0.3800 INCHES NOMINAL
AMDLFirst End Diameter0.5000 INCHES NOMINAL
AMDGFirst End Keyway Depth0.0650 INCHES NOMINAL
AMCZFirst End Keyway Width0.4350 INCHES NOMINAL
AAGZFirst End StyleINDENTED FLAT KEYWAY
MDCLMaterial Document And ClassificationQQ-S-763 FED SPEC SINGLE MATERIAL RESPONSE
MATTMaterialSTEEL COMP 316
ABHPOverall Length21.460 INCHES NOMINAL


Back to Top
Back to Top