Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7430194-01 | 3 - Design Control Reference | 2 - Production Item | OGDEN AIR LOGISTICS CENTER | 98747 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 3120 | 005235253 | A045A0 | 13206 | X | M | 3 | A | N | U | 23 Aug 1974 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 2 | SB | D | 7430194-01 | 98747 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KZ | 1 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TG | R | 722 | Z | Z | A | V | Z | R | 115620 | X | 59240 | BUSHINGS-NOI-I-S |
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
65
Parachutes
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAS | Body Inside Diameter | 1.0500 INCHES MINIMUM AND 1.0600 INCHES MAXIMUM |
ADAR | Body Outside Diameter | 1.2041 INCHES MINIMUM AND 1.2046 INCHES MAXIMUM |
AGFF | Flange Width | 0.0390 INCHES MINIMUM AND 0.0990 INCHES MAXIMUM |
MATT | Material | STEEL COMP 630 OVERALL |
MDCL | Material Document And Classification | AMS 5643 ASSN STD SINGLE MATERIAL RESPONSE OVERALL |
ABHP | Overall Length | 0.3470 INCHES MINIMUM AND 0.4170 INCHES MAXIMUM |
CSYM | Surface Finish | 125.0 MICROINCHES INTERMEDIATE LAYER |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE LEFT END SURFACE OF BODY AND FLANGE |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE OUTSIDE DIAMETER SURFACE OF BODY |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE OUTSIDE DIAMETER SURFACE OF FLANGE |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE RIGHT END SURFACE OF BODY |
STDC | Surface Treatment Document And Classification | QQ-P-416,TY 2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE RIGHT END SURFACE OF LEFT FLANGE |
SFTT | Surface Treatment | CADMIUM LEFT END SURFACE OF BODY AND FLANGE |
SFTT | Surface Treatment | CADMIUM OUTSIDE DIAMETER SURFACE OF BODY |
SFTT | Surface Treatment | CADMIUM OUTSIDE DIAMETER SURFACE OF FLANGE |
SFTT | Surface Treatment | CADMIUM RIGHT END SURFACE OF BODY |
SFTT | Surface Treatment | CADMIUM RIGHT END SURFACE OF LEFT FLANGE |
TEST | Test Data Document | 81349-MIL-I-6866 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |