3431-00-916-2242

WELDING MACHINE,ARC


3431-00-916-2242 (3431009162242, 009162242)
Part Number (1 listing): MILW80037
Summary

FSG 34 / FSC 3431

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 3 Dec 1965

Replacement NSN:

3431-00-163-4345

Replacement Date: 9 Aug 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 3431-00-916-2242 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MILW800374 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 3431-00-916-2242 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
343431009162242T345-A03714X1ANU3 Dec 1965
Code Definitions

34

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Metalworking Machinery

3431

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electric Arc Welding Equipment

009162242

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 3431-00-916-2242

T345-A

Federal Item Identification Guide (FIIG_4065)

03714

Item Naming Code (INC_4080)

3 Dec 1965

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG C - REFERENCE NUMBER | NSN 3431-00-916-2242 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3414JSDMILW80037  81349   CAGE/81349
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

JS

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 3431-00-916-2242 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
19T6309 Aug 1972 3431001634345 19 Jun 1972
19T6309 Aug 1972 3431002043831 19 Jun 1972
19T6319 Aug 1972 3431002221722 19 Jun 1972
19T6309 Aug 1972 3431002398186 19 Jun 1972
19T6319 Aug 1972 3431002558863 19 Jun 1972
19T6319 Aug 1972 3431002733713 19 Jun 1972
19T6319 Aug 1972 3431002757906 19 Jun 1972
19T6309 Aug 1972 3431003519209 19 Jun 1972
19T6309 Aug 1972 3431003602787 19 Jun 1972
19T6309 Aug 1972 3431005291409 19 Jun 1972
19T6309 Aug 1972 3431006334652 19 Jun 1972
19T6309 Aug 1972 3431008288002 19 Jun 1972
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

9T

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

9 Aug 1972

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

3431-00-163-4345

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-204-3831

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-222-1722

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-239-8186

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-255-8863

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-273-3713

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-275-7906

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-351-9209

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-360-2787

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-529-1409

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-633-4652

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3431-00-828-8002

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

19 Jun 1972

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 3431-00-916-2242 Submit RFQ
MRCDecoded RequirementClear Text Reply
APGFDesign TypeGENERATOR
ATJKPower SourceGASOLINE ENGINE
ATJLEngine Manufacturer NameANY ACCEPTABLE
AYHQEngine Manufacturer Identifying NumberANY ACCEPTABLE
ANYPOutput Current Rating In Amps300.0 NOMINAL
CDRRArc Current TypeDC
CDRSMinimum Current At Specified Voltage60 AMP AT 22V
CDRTMaximum Current At Specified Voltage375 AMP AT 35V
CDRWOperator Type For Which DesignedSINGLE
AAXXMounting TypeSKID
CDRYRemote Control DesignNOT INCLUDED
CDRZAuxiliary Power Output DesignINCLUDED
ANLHPower Output Rating3.0 KILOWATTS
ANPNOutput Current TypeAC
ANPPOutput Voltage Rating In Volts115.0 NOMINAL
APTSOutput Frequency Rating60.0 HERTZ NOMINAL
BFLSOutput PhaseSINGLE
ZZZTNondefinitive Spec/Std Data2 TYPE AND
ZZZTNondefinitive Spec/Std Data300 SIZE
SR-1Definitive Government Spec/Std Reference Or Manufacturers Code
SR-1Definitive Government Spec/Std Reference Or Manufacturers Code81349
SR-1Definitive Government Spec/Std Reference Or Manufacturers CodeMILW80037


Back to Top