Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
6893711 | 3 - Design Control Reference | 2 - Production Item | ALLISON TRANSMISSION, INC. | 73342 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
34 | 3439 | 010383413 | T166-G | 04040 | X | 4 | 3 | A | P | A | 3 Apr 1977 |
Miscellaneous Welding, Soldering, and Brazing Supplies and Accessories
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FGKE | FGG4 | 0 | 0 | 1 Jan 2014 | ||||||||||||||||||||||||||
N1R5 | 0 | 0 | J | GG | 1 Jan 2014 |
Not Established
Design Unstable: Items determined by technical decision during the provisioning cycle, during introduction into logistic systems, or at time of item management coding, to be highly subject to either: (A) Design change of the item itself, or (B) Replacement of the item itself through modification of the applicable next-higher assembly. These items will be reviewed for recording when an IM is notified that the item is used by another service/agency, when the design becomes stabilized, or when the item has been in operational use for two years. In all cases these shall be reviewed by IM for IMC change no longer than two years after the IMC J assignment.
Naval Inventory Control Point, Philadelphia, PA 19111û5098
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | CX | 0 | 20 May 1989 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TG | J | 746 | Z | Z | A | V | Z | M | 133300 | C | 63220 | MACHINERY-MACHINES-NOI-SUB3 | 1 |
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
100.2
Welding Equipment and Soldering Supplies
No special type of cargo code applicable
No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
85
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC XF3: Stock Fund (Except Munitions); NAVY: Perishable Subsistence Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
NAVY: Ground Support Equipment-End Items
Department of the Air Force
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
X | S | A | 41 | 1 | 1.0 lbs | 5in x 3in x 3in | 0.026 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | K3 | BG | B | D3 | EC | O | 00 | E | Q | M |
Validated Correction
Secondary Inventory Control Activity (SICA)
Heated General Purpose – Heated 40 F and above
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or MIL-DTL-117, Type II, Class H, Style 2 bag
A-A-1898, Grade II, water resistant cellulosic cushioning
1/2 inch thick
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
Unit container is not an acceptable shipping container.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APGF | Design Type | CHUCK |
ASBW | Multiple Electrode Simultaneous Use Feature | NOT INCLUDED |
ASBX | Electrode Type For Which Designed | CARBON GRAPHITE NONFILLER |
ASBY | Electrode Diameter For Which Designed | 0.222 INCHES NOMINAL |
ASBZ | Replaceable Jaw | NOT INCLUDED |
AHZV | Submersibility | NONSUBMERSIBLE |
ABHP | Overall Length | 2.000 INCHES NOMINAL |
ARFZ | Power Cable | NOT INCLUDED |
ASCD | Oxygen Hose Accommodation | NOT INCLUDED |
APHE | Operation Method | MACHINE |
ASCE | Spare Jaw | NOT INCLUDED |