Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
55055 | 3 - Design Control Reference | 2 - Production Item | H.D. HUDSON MANUFACTURING COMPANY | 29670 | ![]() |
55055 | 3 - Design Control Reference | 2 - Production Item | H.D. HUDSON MANUFACTURING COMPANY | 29670 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
37 | 3740 | 009786859 | T333-A | 31858 | X | 4 | 3 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 6 | 4 Sep 2009 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BNDQ | Agitator | INCLUDED |
CHTM | Air Blower | NOT INCLUDED |
AZKP | Brake Horsepower Rating | 3.500 |
CHWJ | Control Panel | NOT INCLUDED |
CHTQ | Maximum Discharge Rate At Specified Pressure | 5 GPM AT 450 PSI |
ATJK | Power Source | GASOLINE ENGINE |
CHTR | Pressure Regulator | INCLUDED |
CHTT | Solution Pump Type | PISTON |
CHTS | Solution Tank | INCLUDED |
BGTJ | Turntable | NOT INCLUDED |
ASHZ | Spray Type | FOG AND MIST |
BSSM | Tank Capacity | 50.0 GALLONS |