3930-01-008-7044

TRUCK,LIFT,FORK


3930-01-008-7044 (3930010087044, 010087044)
Part Number (1 listing): SC-30
Summary

FSG 39 / FSC 3930

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 29 Aug 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 3930-01-008-7044 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SC-303 - Design Control Reference2 - Production ItemPRIME-MOVER CO THE  93880      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 3930-01-008-7044 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
393930010087044A085A003197X43ANU29 Aug 1975
Code Definitions

39

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Materials Handling Equipment

3930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Warehouse Trucks and Tractors, Self-Propelled

010087044

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 3930-01-008-7044

A085A0

Federal Item Identification Guide (FIIG_4065)

03197

Item Naming Code (INC_4080)

29 Aug 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 3930-01-008-7044 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G51000C1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 3930-01-008-7044 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
132475DSC-30  93880  
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 3930-01-008-7044 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597029 Aug 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Aug 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 3930-01-008-7044 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
51
Code Definitions

51

Originating Activity Code (ORIG_ACTY_CD_4210)


Environmental Protection Agency, Washington, DC 20406

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 3930-01-008-7044 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGCCBattery Compartment Depth24.625 INCHES NOMINAL
AGCABattery Compartment Length31.188 INCHES NOMINAL
AGCBBattery Compartment Width13.750 INCHES NOMINAL
CSZTBoom Backward Tilt Angle8.0 DEGREES NOMINAL
CSNRBoom Forward Tilt Angle3.0 DEGREES NOMINAL
CBBLFeatures ProvidedTELESCOPIC MAST AND FORK SIDE SHIFT AND LOAD LEVELING DEVICE
AGBSFork Length42.000 INCHES NOMINAL
AGCTFork Load Center Distance24.000 INCHES NOMINAL
CWAHFork Spread Distance8.000 INCHES MINIMUM AND 36.000 INCHES MAXIMUM
AGBTFork Width4.000 INCHES NOMINAL
AGDBFork/Platform Maximum Free Lift Height55.000 INCHES
AYXKMaximum Load Rating3000.000 POUNDS
STYLStyle DesignatorSTACKER WITHOUT OUTRIGGERS
AGDDLift Actuation MethodPOWERED
CSKDLift Height Of Forks100.000 INCHES MAXIMUM
AGDCLift Mechanism TypeHYDRAULIC
AKDJPrime Mover TypeELECTRIC MOTOR
AGBWOverall Height With Forks In Highest Position115.250 INCHES NOMINAL
AGBVOverall Height With Forks In Lowest Position71.000 INCHES NOMINAL
ABHPOverall Length111.500 INCHES NOMINAL
ABMKOverall Width33.750 INCHES NOMINAL
FEATSpecial FeaturesFORK/PLATFORM UPRIGHT BOOM
AXJDTransmission TypeMANUAL
CRRFWheel Type And Quantity1 SINGLE SOLID STEERABLE WHEEL
CRRFWheel Type And Quantity2 SINGLE SOLID LOAD WHEEL
AGDSSteering TypeCRAMPING
AGCRStorage Aisle Minimum Width111.000 INCHES


Back to Top