Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
36947 | 3 - Design Control Reference | 2 - Production Item | WARN INDUSTRIES, INC. | 27646 | ![]() |
15204821 | 5 - Replaced / Discontinued | 2 - Production Item | BAE SYSTEMS MARINE LIMITED | K6451 | ![]() |
PN36947 | 5 - Replaced / Discontinued | 2 - Production Item | WARN INDUSTRIES, INC. | 27646 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
39 | 3950 | 015621434 | A02800 | 04575 | X | 4 | 6 | A | N | A | A | 0 | 31 Mar 2008 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZK01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
ZC01 | 1 Jun 2013 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | 36947 | 27646 | ![]() | ||||
4 | 5 | 2 | 4 | 9Z | D | PN36947 | 27646 | ![]() | ||||
4 | 5 | 2 | 4 | ZK | D | 15204821 | K6451 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
United Kingdom
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 31 Mar 2008 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ATWE | Drum Diameter And Location | 5.310 INCHES NOMINAL FIRST DRUM |
ATWF | Drum Flange Diameter And Location | 8.900 INCHES NOMINAL FIRST DRUM |
AKPS | Duty Cycle | INTERMITTENT |
ATWS | Braking Method | ELECTRIC |
ATWG | Capstan Spool Mounting Position | HORIZONTAL |
ATWK | Capstan Spool Quantity | 1 |
BFMF | Cooling Method | AIR TO AIR COOLED |
ACDC | Current Type | DC |
ADZC | Environmental Protection | CORROSION RESISTANT AND FUNGUS RESISTANT AND SPLASH PROOF |
ACSY | Furnished Items And Quantity | 1 MOTOR CONTROLLER AND 1 REMOTE CONTROL AND 1 WIRE ROPE |
APHE | Operation Method | POWERED |
AKNA | Inclosure Type | FULLY INCLOSED |
ATYG | Power Requirement Rating | 1870.0 WATTS |
AAXH | Prime Mover Quantity | 1 |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
CXCY | Part Name Assigned By Controlling Agency | DC 3000 LF-24V INDUSTRIAL DC HOIST |
FEAT | Special Features | GEAR RATIO 199:1; 3-STAGE PLANETARY GEAR REDUCTION; 18:1 CABLE-TO-DRUM RATIO; 8MM WIRE ROPE PROVIDED; 3000 LB RATED LOAD |
ATWP | Travel Rate Per Minute | 15.0 FEET AND 16.0 FEET AND 18.0 FEET AND 20.0 FEET |