4110-01-324-0260

DISPENSER,DRINKING WATER,MECHANICALLY COOLED


4110-01-324-0260 (4110013240260, 013240260)
Part Number (1 listing): WM-8A-2
Summary

FSG 41 / FSC 4110

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 8 Aug 1990

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4110-01-324-0260 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
WM-8A-23 - Design Control Reference2 - Production ItemELKAY MFG CO  59291      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4110-01-324-0260 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414110013240260T235-C04766X43ANU8 Aug 1990
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4110

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Refrigeration Equipment

013240260

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4110-01-324-0260

T235-C

Federal Item Identification Guide (FIIG_4065)

04766

Item Naming Code (INC_4080)

8 Aug 1990

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4110-01-324-0260 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G12000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 4110-01-324-0260 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32475WM-8A-2  59291  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4110-01-324-0260 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59708 Aug 1990
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Aug 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4110-01-324-0260 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
12
Code Definitions

12

Originating Activity Code (ORIG_ACTY_CD_4210)


Bureau of Engraving and Printing, Washington, DC 20228

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4110-01-324-0260 Submit RFQ
MRCDecoded RequirementClear Text Reply
BBLSDraw Off Capacity Per Hour8.0 GALLONS
AZMJDispensing Pressure TypeWATER SUPPLY LINE
AZMMDispenser TypeBASIN TOP CABINET W/TOP DRAW-OFF
AZMNDraw-Off Device TypeBUBBLER
NMBRQuantity2
AZMPRefrigeration Unit CabinetINCLUDED
AWLPCondenser TypeHERMETICALLY SEALED
AZADCondenser Cooling TypeAIR
AWCDWater For Which DesignedFRESH
ACDCCurrent TypeAC
AMSEVoltage Rating120.0 VOLTS NOMINAL
ACZBFrequency Rating60.0 HERTZ NOMINAL
FAAZPhaseSINGLE
AZMSCabinet Top MaterialSTEEL, CORROSION RESISTING
AZMTCabinet Side MaterialSTEEL
ABKWOverall Height28.000 INCHES NOMINAL
ABMKOverall Width18.125 INCHES NOMINAL
ABFYOverall Depth14.250 INCHES NOMINAL
AZMZCabinet Refrigerated Storage SpaceNOT PROVIDED
AZRZShipboard Installation FacilityNOT INCLUDED
FEATSpecial FeaturesWALL MOUNTED


Back to Top