4110-01-505-7531

REFRIGERATION UNIT


4110-01-505-7531 (4110015057531, 015057531)
Part Numbers (2 listings): 6012461-001 | 56261 |
Summary

FSG 41 / FSC 4110

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 14 Mar 2003

Unit Weight: 206.0 lbs

Unit Size: 4ft x 28in x 29.5in

Unit Pack Cube: 22.944 cu ft

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4110-01-505-7531 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
6012461-0013 - Design Control Reference1 - Incomplete Part NumberBAE SYSTEMS NATIONAL SECURITY  12436    CAGE 12436  
562613 - Design Control Reference2 - Production ItemELECTRO IMPULSE LABORATORY INC.  91161      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4110-01-505-7531 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414110015057531A2390077777X41BNBA014 Mar 2003
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4110

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Refrigeration Equipment

015057531

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4110-01-505-7531

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

14 Mar 2003

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4110-01-505-7531 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FUU400FEFH1 Mar 2003
YJ011 Sep 2005
ZN011 Aug 2006
ZB011 Jun 2007
WP011 Oct 2007
ZU011 May 2008
ZT011 Mar 2009
ZH011 Oct 2014
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

FHDSOR

Depot Source of Repair Codes (DSOR_0903)


Ogden Air Logistics Center (OO-ALC), Hill AFB, UT


FLIS - SEG C - REFERENCE NUMBER | NSN 4110-01-505-7531 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
31CZZ6012461-001  12436   CAGE/12436
32CZZ56261  91161  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

C

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing. The drawing is available for unlimited use but under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4110-01-505-7531 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597014 Mar 2003
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

14 Mar 2003

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4110-01-505-7531 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4110-01-505-7531 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFGZCU1TEA0
Code Definitions

FGZ

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG W - PACKAGING DATA | NSN 4110-01-505-7531 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP521000206.0 lbs4ft x 28in x 29.5in22.944 cu ft67.0 lbs33in x 19in x 15.9in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00ZZZZZZZ00BZZA
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

52

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Container, watervaporproof bag, sealed, container

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

206.0 lbs

Unit Pack Weight (UP_WT_5153)

4ft x 28in x 29.5in

Unit Pack Size (UP_SZ_5154)

22.944 cu ft

Unit Pack Cube (UP_CU_5155)

67.0 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

33in x 19in x 15.9in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4110-01-505-7531 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationF-16 R-IAIS
AFJKCubic Measure5.185 CUBIC FEET
FTLDFunctional DescriptionUNIT PROVIDES COOLING AIR OF 27 (PLUS 5 TO MINUS 10) DEGREES C, TO COOLLRUS USING AN EXTERNAL BLOWER UNIT PN:6102460-001
ABKWOverall Height15.720 INCHES MAXIMUM
ABHPOverall Length30.000 INCHES MAXIMUM
ABMKOverall Width19.000 INCHES MAXIMUM
FEATSpecial FeaturesCLEANABLE AIR FILTER; CONDENSATE DRAIN; CONDENSER AIR EXHAUST FAN WITH PROTECTIVE COVER; ESD GROUND
CSBHVoltage In Volts And Current Type208.0 AC AND 28.0 DC
MARKSpecial MarkingsWARNING 230 VOLTS;TWO MAN LIFT REQUIRED
SFTTSurface TreatmentPAINT


Back to Top