Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
95500 | 3 - Design Control Reference | 2 - Production Item | DRS ENVIRONMENTAL SYSTEMS, INC. | 5RQL2 | ![]() |
95500 | 3 - Design Control Reference | 9 - No Longer Used | KECO INDUSTRIES INC. | 94833 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
41 | 4120 | 001199384 | A505G0 | 06486 | X | M | 3 | A | Y | A | 6 Jan 1973 |
Refrigeration, Air Conditioning, and Air Circulating Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Nov 2005 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | CX | 1 | 1 | CX | 0 | 21 Apr 1985 | 4120004098604 | 20 Apr 1985 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE | 72E | W | D | Z | H | D | W | 114125 | A | 58510 | AIR-COOLER-CONDITIONER-ETC-SUB-1 | 1 |
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Engineer and Material Handling Equipment, Test/Tool sets and Equipment
Corrosive materials, UN class 8 (corrosive label)
Protected (Sensitive). Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN).
Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWLX | Electric Motor Quantity | 2 |
AZSD | Compressor Unit Type | OPEN |
AZAD | Condenser Cooling Type | AIR |
ARNA | Coolant Type | FREON-12 |
ACDC | Current Type | AC OR DC |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
ANCY | Horsepower Rating | 3.000 |
AAXX | Mounting Type | TRAILER |
AZSF | Nominal Cooling Capacity | 800.0 CUBIC FEET PER MINUTE |
ATJK | Power Source | GASOLINE ENGINE |
ALCD | Usage Design | CONDENSER |
AMSE | Voltage Rating | 208.0 POUNDS PER HOUR WET AND 24.0 POUNDS PER HOUR WET |
SFTT | Surface Treatment | ENAMEL |