Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
F9000H-1SA | 3 - Design Control Reference | 2 - Production Item | DRS ENVIRONMENTAL SYSTEMS, INC. | 5RQL2 | |
F9000H-1SA | 3 - Design Control Reference | 9 - No Longer Used | KECO INDUSTRIES INC. | 94833 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
41 | 4120 | 013264370 | A505G0 | 06486 | N | 4 | 3 | A | Y | A | 0 | 24 Sep 1990 |
Refrigeration, Air Conditioning, and Air Circulating Equipment
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | A002 | 1 | G | A | D | TB | AJ | 1 Oct 1997 | ||||||||||||||||||||||
MA46 | MA24 | 1 | G | 5 | D | TB | 1 Oct 1997 | |||||||||||||||||||||||
ZC01 | 1 Mar 1998 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
An activitiy within the Army is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Tobyhanna Army Depot (TYAD), PA
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | F9000H-1SA | 5RQL2 | |||||||
3 | 9 | 5 | AJ | ZZCLP | G3 | F9000H-1SA | 94833 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 24 Sep 1990 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AJ | 658 | Z | 9 | A | B | Z | W | 114126 | Z | 30740 | AIR-COOLER-AIR-CONDITIONERS |
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Warner Robins Air Logistics Center, 455 Byron St, Robins AFB, GA 31098-1860
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Department of the Air Force
Department of the Army
U.S. Marine Corps
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWLX | Electric Motor Quantity | 3 |
CYGG | Cabinet Material | ALUMINUM-COPPER FREE |
AZSD | Compressor Unit Type | CLOSED |
AZAD | Condenser Cooling Type | AIR |
ARNA | Coolant Type | FREON-22 |
CYJE | Cooling Capacity In Btu Per Hour | 9000.0 NOMINAL |
ACDC | Current Type | AC |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
CYKM | Heating Capacity In Btu Per Hour | 6200.0 NOMINAL |
AAXX | Mounting Type | FLOOR OR WALL |
AZSF | Nominal Cooling Capacity | 375.0 CUBIC FEET PER MINUTE |
AZSH | Nominal Heating Capacity | 375.0 CUBIC FEET PER MINUTE |
ATJK | Power Source | ELECTRIC MOTOR |
FAAZ | Phase | SINGLE |
FEAT | Special Features | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;ACCESSORIES-NOT INCL.;SGL PKG,COMPACT HORIZONTAL UNIT |
ALCD | Usage Design | COMPRESSOR,CONDENSER FAN,EVAPORATOR FAN |
AMSE | Voltage Rating | 115.0 VOLTS NOMINAL |
SFTT | Surface Treatment | ENAMEL |
TEST | Test Data Document | 94833-F9000-1SA DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |