Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
F18HMPI | 3 - Design Control Reference | 2 - Production Item | DRS ENVIRONMENTAL SYSTEMS, INC. | 5RQL2 | |
F18HMPI | 3 - Design Control Reference | 9 - No Longer Used | KECO INDUSTRIES INC. | 94833 | |
13222E9160 | 5 - Replaced / Discontinued | 2 - Production Item | CECOM LR CENTER | 97403 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
41 | 4120 | 013271316 | A505G0 | 06486 | X | 4 | 3 | A | Y | A | A | 0 | 7 Oct 1990 |
Refrigeration, Air Conditioning, and Air Circulating Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | A002 | 1 | G | A | D | TB | AJ | BF | BD | AM | 1 Oct 1997 | |||||||||||||||||||
F2CL | F4CL | 1 | G | 2 | D | FH | 1 Nov 1999 | |||||||||||||||||||||||
ZU01 | 1 May 2008 | |||||||||||||||||||||||||||||
ZC01 | 1 Nov 2010 | |||||||||||||||||||||||||||||
YD01 | 1 Jul 2016 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
An activitiy within the Army is providing depot maintenance support.
Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.
Exception Item (Depot Reparable Component or SICA Managed Consumable). This code identifies SICA managed depot reparable components, or SICA managed consumables wherein the SICA cannot use repaired items, assigned to another service which has responsibility for the logistics functions of single submitter of cataloging data, acquisition and disposal authority. Supply support requirements will be submitted by the SICA to the PICA on MIPRs unless otherwise directed by PICA. The SICA service has retained the wholesale stock, store, and issue functions in support of SICA activities and has retained depot repair capability, where applicable. Retention of depot maintenance capability for the depot reparable components requires documented justification by the SICA to the PICA via JLC Form 9. If the PICA and SICA cannot reach an agreement, the documentation will be forwarded to the joint MISMOs for a decision. The SICA CMD will reflect Source of Supply or SoS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Tobyhanna Army Depot (TYAD), PA
Ogden Air Logistics Center (OO-ALC), Hill AFB, UT
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | F18HMPI | 5RQL2 | |||||||
3 | 9 | 5 | AJ | F18HMPI | 94833 | |||||||
5 | 2 | 1 | ZZ | 13222E9160 | 97403 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 7 Oct 1990 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AJ | 593 | G | 9 | A | V | D | W | 114125 | Z | 58510 | AIR-COOLER-CONDITIONER-HEAT-PUMP |
U.S. Army Soldier's Biological and Chemical, Command, Natick, MA 01760
Motors and Parts, (machinery and parts), (less than 35 feet)
Nonflammable compressed gas, UN class 2 (nonflammable gas label; Except: (1) oxygen which requires an oxidizer label, and (2) fluorine which requires poison and oxidizer labels)
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.
Variable Rating
No Variation. NMFC and UFCC Match.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Department of the Army
Department of the Air Force
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | B | ZZ | Z | 000 | 323.0 lbs | 28in x 22in x 4ft 4in | 18.537 cu ft | 0.1 lbs | 0.1in x 0.1in x 0.1in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ | ZZ |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Unheated General Purpose
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWLX | Electric Motor Quantity | 3 |
CYGG | Cabinet Material | ALUMINUM-COPPER FREE |
AZSD | Compressor Unit Type | CLOSED |
AZAD | Condenser Cooling Type | AIR |
ARNA | Coolant Type | FREON-22 |
CYJE | Cooling Capacity In Btu Per Hour | 18000.0 NOMINAL |
ACDC | Current Type | AC |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
CYKM | Heating Capacity In Btu Per Hour | 14300.0 NOMINAL |
AAXX | Mounting Type | FLOOR OR WALL |
AZSF | Nominal Cooling Capacity | 640.0 CUBIC FEET PER MINUTE |
AZSH | Nominal Heating Capacity | 630.0 CUBIC FEET PER MINUTE |
ATJK | Power Source | ELECTRIC MOTOR |
FAAZ | Phase | THREE |
FEAT | Special Features | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;ACCESSORIES-NOT INCL. |
ALCD | Usage Design | COMPRESSOR,CONDENSER FAN,EVAPORATOR FAN |
AMSE | Voltage Rating | 208.0 VOLTS NOMINAL |
SFTT | Surface Treatment | ENAMEL |
TEST | Test Data Document | 94833-F18TMPI DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |