4120-01-659-8166

AIR CONDITIONER


4120-01-659-8166 (4120016598166, 016598166)
Part Number (1 listing): AAC-140-4XT-HC
Summary

FSG 41 / FSC 4120

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 16 Dec 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4120-01-659-8166 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AAC-140-4XT-HC3 - Design Control Reference2 - Production ItemEIC SOLUTIONS, INC.  9W159      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4120-01-659-8166 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414120016598166A505G006486X43ANAA016 Dec 2016
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4120

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Air Conditioning Equipment

016598166

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4120-01-659-8166

A505G0

Federal Item Identification Guide (FIIG_4065)

06486

Item Naming Code (INC_4080)

16 Dec 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4120-01-659-8166 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Dec 2016
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4120-01-659-8166 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
432E9ZDAAC-140-4XT-HC  9W159  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 4120-01-659-8166 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZA
Code Definitions

ZA

Originating Activity Code (ORIG_ACTY_CD_4210)


Australia

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4120-01-659-8166 Submit RFQ
MRCDecoded RequirementClear Text Reply
CYGGCabinet MaterialSTEEL CORROSION RESISTING
AZADCondenser Cooling TypeAIR
CYJECooling Capacity In Btu Per Hour400.0 NOMINAL
ACDCCurrent TypeDC
AFSSDesign Current Rating In Amps4.0 MINIMUM
ABKWOverall Height7.25 INCHES NOMINAL
ABHPOverall Length10.18 INCHES NOMINAL
ABMKOverall Width7.0 INCHES NOMINAL
FEATSpecial FeaturesEQUIPPED WITH A ADJUSTABLE THERMOSTAT,ONLY NEMA 4X WITH MODEL NUMBER BEGINING WITH AAC-140-4XT ARE DESIGNED FOR THE HOT SIDE OF THE AIR CONDITIONER (OUTSIDE THE ENCLOSURE)TO TOLERATE EXPOSURE TO WATER,NEVER EXPOSE THE COLD SIDE (INSIDE THE ENCLOSURE) TO WATER,VERTICAL MOUNTING ONLY,NO COMPRESSOR,REFRIGERANT OR FILTERS REQUIRED,NEMA 4X TYPE 304 STAINLESS STEEL CONSTRUCTION FOR INDOOR OR OUTDOOR USE,CAN BE THROUGH-MOUNT,FLUSH-MOUNT OR RECESSED-MOUNT,MOUNTING GASKET AND STAINLESS STEEL FASTENERS INCLUDED
AMSEVoltage Rating24.0 VOLTS MINIMUM AND 28.0 VOLTS MAXIMUM


Back to Top
Back to Top