4140-00-004-9949

FAN,VANEAXIAL


4140-00-004-9949 (4140000049949, 000049949)
Part Numbers (2 listings): 123SCEC5150-7 | 81D05-1 |
Summary

FSG 41 / FSC 4140

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 19 Jun 1972

Unit Weight: 140.0 lbs

Unit Size: 10in x 12in x 9in

Unit Pack Cube: 0.625 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4140-00-004-9949 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
123SCEC5150-71 - Source of Control Reference3 - Reparable ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
81D05-13 - Design Control Reference3 - Reparable ItemGRIMES AEROSPACE COMPANY  72914    CAGE 72914  
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

3 - Reparable Item

Reference Number Variation Code (DRN_4780)


A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.


FLIS - SEG A - IDENTIFICATION | NSN 4140-00-004-9949 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414140000049949A087A004245XN9ANA019 Jun 1972
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4140

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Fans, Air Circulators, and Blower Equipment

000049949

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4140-00-004-9949

A087A0

Federal Item Identification Guide (FIIG_4065)

04245

Item Naming Code (INC_4080)

19 Jun 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

N

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4140-00-004-9949 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N2R43BVEKENIGG1 Apr 1991
YJ011 Apr 1991
ZF011 Apr 1996
YD011 Mar 2017
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

B

Acquisition Method Suffix Code (AMSC_2876)


Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.

V

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Navy is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

NIDSOR

Depot Source of Repair Codes (DSOR_0903)


Fleet Readiness Center, South West (FRC-SW), North Island, San Diego CA

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 4140-00-004-9949 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1135KEB123SCEC5150-7  26512   CAGE/26512
331KEA81D05-1  72914   CAGE/72914
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3

Reference Number Variation Code (RNVC_4780)


A vendor's reference (part) number on a source control item, as defined in MIL-STD-100A, which is reparable through the removal, exchange, and reinstallation of component parts. The related source control document number will also reflect the code 3. This code is limited to a type 1B or 4B item identification.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4140-00-004-9949 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX08 Jun 1975
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Jun 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4140-00-004-9949 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KEW752Z9AHZJ061920X34690FANS-ELEC-NOI-IN-BARREL-BOX-CRATE1
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

W

Less Than Carload (LCL_CD_2760)


Rating Variable

752

Water Commodity Code (WRT_CMDTY_CD_9275)


Prefabricated Structures & Scaffolding

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061920

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34690

Uniform Freight Classification (UFC_CD_MODF_3040)

FANS-ELEC-NOI-IN-BARREL-BOX-CRATE

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 4140-00-004-9949 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNNRPCU0EEA0
Code Definitions

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

E

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: (1) Iram program intensive management reparables (2) material (expendable ordnance) requiring lot and serial-# control but which is reported by serial-# only.

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 4140-00-004-9949 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APBDW1000140.0 lbs10in x 12in x 9in0.625 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00K3BGBRC00A03FFFM
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

B

Item Type Storage Code (ITM_TYP_STOR_5156)


Unheated General Purpose

DW

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 52 as follows: Item shall be cleaned, wrapped, blocked and braced in an interior carton fabricated in accordance with ASTM-D5118, Class domestic. MIL-PRF-131 barrier material, sealed as required, shall be utilized around the first container. The cushioning, to be specified under the cushioning code and in the thickness required to adequately protect the item, shall be placed between the barrier and the outer container.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

140.0 lbs

Unit Pack Weight (UP_WT_5153)

10in x 12in x 9in

Unit Pack Size (UP_SZ_5154)

0.625 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

K3

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or MIL-DTL-117, Type II, Class H, Style 2 bag

BG

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


A-A-1898, Grade II, water resistant cellulosic cushioning

B

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


1/2 inch thick

RC

Unit Container Code (UNIT_CTNR_CD_5166)


NAVICP Drawing No. 15450, modular reusable container for packaging depot level repairables.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

A

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level A packing protection.

03

Special Marking Code (SP_MKG_CD_5169)


Mehod 50

F

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Packing is not required; the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4140-00-004-9949 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKCVDrive TypeDIRECT
AGBDElectrical Connection TypeCORD W/ATTACHED PLUG
ABMZDiameter8.460 INCHES NOMINAL
ADNKFlow DirectionINWARD
FREQFrequency In Hertz400.0
CWLXHousing Inside Diameter10.500 INCHES NOMINAL
MATTMaterialALUMINUM ALLOY OVERALL
AXHRMounting Facility Type And Quantity6 UNTHREADED HOLE
AKNAInclosure TypeFULLY INCLOSED
ABRYLength9.500 INCHES NOMINAL
CWLYPrime Mover Drive Shaft Bearing TypeBALL
NMBRQuantity1
ZZZYReference Number Differentiating CharacteristicsDIFFERENTIATED BY SOURCE CONTROL DRAWING
AYSYRotation Direction For Which DesignedCLOCKWISE
FAAZPhaseTHREE
FEATSpecial FeaturesINCLUDES METER TIME TOTALIZING
CSBHVoltage In Volts And Current Type115.0 AC
ABBBSpeed AdjustmentsSINGLE SPEED
AAYDStage Quantity1
STYLStyle DesignatorFIXED


Back to Top
Back to Top