Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
033238 | 3 - Design Control Reference | 2 - Production Item | ROTRON INCORPORATED | 82877 | |
AXIMAX3-593JH | 5 - Replaced / Discontinued | 9 - No Longer Used | ROTRON INCORPORATED | 82877 | |
A0-61876 | 5 - Replaced / Discontinued | 9 - No Longer Used | ROTRON INCORPORATED | 82877 | |
810001-822 | 7 - Vendor Item Drawing Reference | 2 - Production Item | BAE SYSTEMS NATIONAL SECURITY | 12436 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
41 | 4140 | 001058391 | A087A0 | 04245 | X | 4 | 3 | A | N | U | 12 Jul 1968 |
Refrigeration, Air Conditioning, and Air Circulating Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DGX1 | 5 | H | 1 Jan 2007 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | CX | 033238 | 82877 | |||||||
4 | 5 | 9 | 4 | CX | B | A0-61876 | 82877 | |||||
5 | 9 | E | CX | B | AXIMAX3-593JH | 82877 | ||||||
1 | 7 | 2 | A | CX | D | 810001-822 | 12436 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | D4 | 0 | 5 Mar 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 752 | Z | 9 | A | H | Z | J | 061920 | X | 34690 | FANS-ELEC-NOI-IN-BARREL-BOX-CRATE |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Prefabricated Structures & Scaffolding
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKCV | Drive Type | DIRECT |
AGBD | Electrical Connection Type | TERMINAL BLOCK |
CQKX | Air Flow Rate | 82.000 CUBIC FEET PER MINUTE NOMINAL |
AEHY | Ambient Temp At Full Rated Power | 0.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
ABMZ | Diameter | 2.625 INCHES NOMINAL |
ADZC | Environmental Protection | FUNGUS RESISTANT AND HUMIDITY PROOF AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF |
ADNK | Flow Direction | OUTWARD |
FREQ | Frequency In Hertz | 400.0 |
CWLX | Housing Inside Diameter | 2.802 INCHES MINIMUM AND 2.822 INCHES MAXIMUM |
MATT | Material | ALUMINUM ALLOY OVERALL |
AXHR | Mounting Facility Type And Quantity | 2 RING |
AEQC | Operating Speed At Rated Capacity In Rpm | 11600.0 |
AKNA | Inclosure Type | FULLY INCLOSED |
ABRY | Length | 2.281 INCHES MINIMUM AND 2.343 INCHES MAXIMUM |
CWLY | Prime Mover Drive Shaft Bearing Type | BALL |
CSYL | Prime Mover Power Rating | 0.032 HORSEPOWER |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
NMBR | Quantity | 1 |
AYSY | Rotation Direction For Which Designed | COUNTERCLOCKWISE |
FAAZ | Phase | THREE |
CSBH | Voltage In Volts And Current Type | 115.0 AC |
ABBB | Speed Adjustments | SINGLE SPEED |
AAYD | Stage Quantity | 1 |
AJLY | Static Pressure At Specified Air Flow Rate | 0.0 INCHES OF WATER |
STYL | Style Designator | FIXED |
STDC | Surface Treatment Document And Classification | MIL-E-5557,TY 4 MIL SPEC SINGLE TREATMENT RESPONSE OVERALL |
SFTT | Surface Treatment | ENAMEL OVERALL |