Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
D5-19-4890 | 1 - Source of Control Reference | 2 - Production Item | EDGEWOOD CHEMICAL BIOLOGICAL CENTER | 81361 | |
7W66049 | 3 - Design Control Reference | 2 - Production Item | HOWDEN NORTH AMERICA INC. | 75477 | |
7W66049 | 5 - Replaced / Discontinued | 9 - No Longer Used | NEW PHILADELPHIA FAN CO | 09519 |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
41 | 4140 | 001721804 | A087A0 | 04245 | X | 4 | 3 | B | N | A | A | 0 | 30 Aug 1972 |
Refrigeration, Air Conditioning, and Air Circulating Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A003 | A403 | 1 | G | E | 1 Oct 1998 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 1 | 2 | 1 | BF | D | D5-19-4890 | 81361 | |||||
3 | 2 | 4 | ZZ | 7W66049 | 75477 | |||||||
3 | 5 | 9 | 4 | BF | D | 7W66049 | 09519 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | CX | 0 | 8 Jun 1975 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC | W | 752 | Z | 9 | A | H | Z | J | 061920 | X | 34690 | FANS-ELEC-NOI-IN-BARREL-BOX-CRATE | 1 |
U.S. Army Chemical Research, Development and Engineering Center Aberdeen Proving Ground, MD 21010-5423
Rating Variable
Prefabricated Structures & Scaffolding
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
US Army Soldier's Biological and Chemical Command, Natick, MA 01760
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | B | ZZ | Z | 500.0 lbs | 15.7in x 15.7in x 13.8in | 1,974.000 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Unheated General Purpose
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKCV | Drive Type | DIRECT |
AGBD | Electrical Connection Type | WIRE LEAD |
CQKX | Air Flow Rate | 1200.0 CUBIC FEET PER MINUTE NOMINAL |
AEHY | Ambient Temp At Full Rated Power | -25.0 DEG FAHRENHEIT AND 140.0 DEG FAHRENHEIT |
ADNK | Flow Direction | INWARD |
FREQ | Frequency In Hertz | 60.0 |
CWLX | Housing Inside Diameter | 14.690 INCHES MINIMUM AND 15.000 INCHES MAXIMUM |
AXHR | Mounting Facility Type And Quantity | 16 UNTHREADED HOLE |
AEQC | Operating Speed At Rated Capacity In Rpm | 3450.0 |
AKNA | Inclosure Type | PARTIALLY INCLOSED |
ABRY | Length | 11.750 INCHES MINIMUM AND 12.000 INCHES MAXIMUM |
CSYL | Prime Mover Power Rating | 1.000 HORSEPOWER |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
FAAZ | Phase | THREE |
CSBH | Voltage In Volts And Current Type | 208.0 AC |
ABBB | Speed Adjustments | SINGLE SPEED |
AAYD | Stage Quantity | 1 |
AJLY | Static Pressure At Specified Air Flow Rate | 3.1 INCHES OF WATER |
STYL | Style Designator | FIXED |