4140-00-203-3714

FAN,CENTRIFUGAL


4140-00-203-3714 (4140002033714, 002033714)
Part Numbers (3 listings): 95G2591 | DB | 2NB61082 |
Summary

FSG 41 / FSC 4140

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

4140-00-752-9858

Replacement Date: 21 Aug 1974

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4140-00-203-3714 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
95G25913 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
DB5 - Replaced / Discontinued9 - No Longer UsedHOWARD INDUSTRIES  81041      
2NB610825 - Replaced / Discontinued9 - No Longer UsedZERO CORP  03522      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4140-00-203-3714 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414140002033714A087A004254X49ANU1 Jan 1963
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4140

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Fans, Air Circulators, and Blower Equipment

002033714

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4140-00-203-3714

A087A0

Federal Item Identification Guide (FIIG_4065)

04254

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4140-00-203-3714 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4140-00-203-3714 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
35969ZB2NB61082  03522  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4140-00-203-3714 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3D411D4021 Aug 1974 4140007529858 7 Mar 1969
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

D4

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Belvoir Research, Development and, Engineering Center, Fort Belvoir, VA 22060-5606

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Aug 1974

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

4140-00-752-9858

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

7 Mar 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4140-00-203-3714 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
W752Z9AHZJ061920X34690FANS-ELEC-NOI-IN-BARREL-BOX-CRATE1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


W

Less Than Carload (LCL_CD_2760)


Rating Variable

752

Water Commodity Code (WRT_CMDTY_CD_9275)


Prefabricated Structures & Scaffolding

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061920

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34690

Uniform Freight Classification (UFC_CD_MODF_3040)

FANS-ELEC-NOI-IN-BARREL-BOX-CRATE

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4140-00-203-3714 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKCVDrive TypeDIRECT
CQKXAir Flow Rate100.0 CUBIC FEET PER MINUTE MAXIMUM
CXCBDischarge DirectionHORIZONTAL
ADZCEnvironmental ProtectionDUSTPROOF
MATTMaterialSTEEL OVERALL
AEQCOperating Speed At Rated Capacity In Rpm3000.0
AJLWOutlet Inside Diameter2.156 INCHES NOMINAL
CRWJOutlet LocationTOP
AKNAInclosure TypePARTIALLY INCLOSED
AKDJPrime Mover TypeELECTRIC MOTOR
CWLYPrime Mover Drive Shaft Bearing TypeSLEEVE
CSYLPrime Mover Power Rating0.020 HORSEPOWER
NMBRQuantity2
AYSYRotation Direction For Which DesignedCLOCKWISE AND COUNTERCLOCKWISE
FAAZPhaseSINGLE
CSBHVoltage In Volts And Current Type115.0 AC
AAYDStage Quantity2
AJLYStatic Pressure At Specified Air Flow Rate0.0 INCHES OF WATER
SFTTSurface TreatmentENAMEL BLADE
SFTTSurface TreatmentPAINT HOUSING INSIDE
SFTTSurface TreatmentPAINT HOUSING OUTSIDE


Back to Top
Back to Top