4140-01-062-3818

FAN,VANEAXIAL


4140-01-062-3818 (4140010623818, 010623818)
Part Numbers (2 listings): A0-74536 | 009-1883-010 |
Summary

FSG 41 / FSC 4140

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 15 Jul 1978

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4140-01-062-3818 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
A0-745363 - Design Control Reference2 - Production ItemROTRON INCORPORATED  82877    CAGE 82877  
009-1883-0107 - Vendor Item Drawing Reference2 - Production ItemROCKWELL COLLINS, INC.  13499    CAGE 13499  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4140-01-062-3818 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
414140010623818A087A004245XM3ANU15 Jul 1978
Code Definitions

41

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Refrigeration, Air Conditioning, and Air Circulating Equipment

4140

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Fans, Air Circulators, and Blower Equipment

010623818

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4140-01-062-3818

A087A0

Federal Item Identification Guide (FIIG_4065)

04245

Item Naming Code (INC_4080)

15 Jul 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4140-01-062-3818 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BZN9ZD00ZGHKE1 Sep 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 4140-01-062-3818 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4325KEAA0-74536  82877   CAGE/82877
4721KEB009-1883-010  13499   CAGE/13499
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4140-01-062-3818 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX026 Aug 1986
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

26 Aug 1986

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4140-01-062-3818 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE752Z9AHZJ061920X34690FANS-ELEC-NOI-IN-BARREL-BOX-CRATE
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

752

Water Commodity Code (WRT_CMDTY_CD_9275)


Prefabricated Structures & Scaffolding

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061920

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34690

Uniform Freight Classification (UFC_CD_MODF_3040)

FANS-ELEC-NOI-IN-BARREL-BOX-CRATE

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4140-01-062-3818 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU1EA0
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4140-01-062-3818 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKCVDrive TypeDIRECT
AGBDElectrical Connection TypeTERMINAL BLOCK
CQKXAir Flow Rate60.0 CUBIC FEET PER MINUTE NOMINAL
AEHYAmbient Temp At Full Rated Power-55.0 DEG CELSIUS AND 85.0 DEG CELSIUS
ABMZDiameter1.875 INCHES MINIMUM AND 1.890 INCHES MAXIMUM
ADZCEnvironmental ProtectionMOISTURE RESISTANT AND VIBRATION PROOF
ADNKFlow DirectionINWARD
FREQFrequency In Hertz400.0
CWLXHousing Inside Diameter2.176 INCHES NOMINAL
MATTMaterialALUMINUM OVERALL
AXHRMounting Facility Type And Quantity1 CLAMP RING
AEQCOperating Speed At Rated Capacity In Rpm19475.0
AKNAInclosure TypeFULLY INCLOSED
ABRYLength1.406 INCHES NOMINAL
CWLYPrime Mover Drive Shaft Bearing TypeBALL
CSYLPrime Mover Power Rating0.050 HORSEPOWER
AKDJPrime Mover TypeELECTRIC MOTOR
NMBRQuantity1
AYSYRotation Direction For Which DesignedCOUNTERCLOCKWISE
FAAZPhaseTHREE
CSBHVoltage In Volts And Current Type200.0 AC
ABBBSpeed AdjustmentsSINGLE SPEED
AAYDStage Quantity1
AJLYStatic Pressure At Specified Air Flow Rate0.0 INCHES OF WATER
STYLStyle DesignatorFIXED
SFTTSurface TreatmentENAMEL OVERALL


Back to Top