Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
C5-45-3183 | 3 - Design Control Reference | 2 - Production Item | EDGEWOOD CHEMICAL BIOLOGICAL CENTER | 81361 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
42 | 4230 | 007359931 | A23900 | 26970 | N | M | 2 | B | N | A | A | 0 | 1 Jan 1961 |
Firefighting, Rescue, and Safety Equipment; and Environmental Protection Equipment and Materials
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
The approved item name applied to this item exists for use exclusively with the partial descriptive method of item identification - Miscellaneous Items Federal Item Identification Guide A239.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
A002 | A402 | 1 | G | A | E | BL | BD | 1 Oct 1998 | ||||||||||||||||||||||
F5AJ | F5BF | 1 | G | 6 | E | 00 | 1 Oct 1998 | |||||||||||||||||||||||
MA24 | MA39 | 1 | G | 5 | E | BL | 1 Oct 1998 | |||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
An activitiy within the Army is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Requisitioning Activity Funded Items. This code identifies items wherein SICA activities have been authorized by their parent Service to submit requisitions directly to the PICA. These items are usually managed as consumable (expense) items by the SICA Service. The SICA CMD will reflect the Source of Supply or Source of Supply Modifiers compatible with the PICA managing activities and may reflect the Acquisition Advice Code (AAC) of the PICA. The PICA will not be entered in the DAAS IMM field.
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Consumable Item or Ammunition
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 98 | 0 | 1 Feb 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
760 | Z | R | A | V | Z | Z | 000000 | X | 00000 | NO-NMFC-FREIGHT-DESCRIPTION | 1 |
Steel Storage Tanks and Pontoons (See 860)
No special type of cargo code applicable
No special handling required. Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
No Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
US Army Soldier's Biological and Chemical Command, Natick, MA 01760
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
OTHER SERVICE-MANAGED, STOCKED, AND ISSUED (For Service use only if Secondary Inventory Control Activity Level of Authority (SICA LOA) is 8D and Nonconsumable Item Material Support Code (NIMSC) is 6.) Issue, transfer or shipment is not subject to specialized controls other than those imposed by the Service requisitioning policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions may require a fund citation and will be submitted in accordance with the Service requisitioning procedures.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Department of the Army
Department of the Air Force
U.S. Marine Corps
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | B | ZZ | Z | 9,999.9 lbs | 7ft 5in x 4ft 5.5in x 4ft 10in | 9,999.999 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Unheated General Purpose
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
TEXT | General Characteristics Item Description | O/A INCL SKID 78 IN. LG 44 IN. W 47 IN. H; TANK CRES 500 GAL CAP. W/FLUID AGITATOR SYST; W/BLEND HOPPER W/FILL HOSE; EQUIP APPL CML DECONTAMINATION APPARATUS PWR DRIVEN SKID MTD MODEL M12 |