4310-00-595-3014

COMPRESSOR UNIT,RECIPROCATING


4310-00-595-3014 (4310005953014, 005953014)
Part Numbers (2 listings): MC-2 | MIL-C-8498 |
Summary

FSG 43 / FSC 4310

DEMIL: A

DEMIL INT:

HMIC: Y

Date Created: 1 Jan 1963

Unit Weight: 1,090.0 lbs

Unit Size: 7ft 7in x 47.3in x 4ft 4.1in

Unit Pack Cube: 129.776 cu ft

Replacement NSN:

4310-00-693-2652

Replacement Date: 8 Oct 1965

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4310-00-595-3014 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MC-22 - Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-C-84984 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 4310-00-595-3014 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
434310005953014A026A029301X44AYA01 Jan 1963
Code Definitions

43

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Pumps and Compressors

4310

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Compressors and Vacuum Pumps

005953014

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4310-00-595-3014

A026A0

Federal Item Identification Guide (FIIG_4065)

29301

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

4

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

Y

Hazardous Material Indicator Code (HMIC_0865)


Indicates information is in the Hazardous Materials Information Resource System (HMIRS).

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4310-00-595-3014 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
ZP011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4310-00-595-3014 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4214SBD1MC-2  81349   CAGE/81349
4413SBDMIL-C-8498  81349   CAGE/81349
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Justification Code (RNJC_2750)


Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4310-00-595-3014 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3AX11AX08 Oct 1965 4310006932652 1 Apr 1965
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

AX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43216-5000

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Oct 1965

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

4310-00-693-2652

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

1 Apr 1965

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4310-00-595-3014 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
594RDZVDW118100Z60340COMPRESSORS--AIR--NOI--OR-AIR-ENDS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


594

Water Commodity Code (WRT_CMDTY_CD_9275)


Pumps and Parts, (machinery and parts), (less than 35 feet)

R

Type Cargo Code (TYPE_CGO_CD_9260)


Flammable liquids, UN class 3 (flammable liquids label)

D

Special Handling Code (SP_HDLG_CD_9240)


Protected (Sensitive). Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN).

Z

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.

V

Air Commodity Code (AIR_CMTY_HDLG_9215)


Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.

D

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

118100

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

60340

Uniform Freight Classification (UFC_CD_MODF_3040)

COMPRESSORS--AIR--NOI--OR-AIR-ENDS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 4310-00-595-3014 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP10001,090.0 lbs7ft 7in x 47.3in x 4ft 4.1in129.776 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZ00AZZA
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

1,090.0 lbs

Unit Pack Weight (UP_WT_5153)

7ft 7in x 47.3in x 4ft 4.1in

Unit Pack Size (UP_SZ_5154)

129.776 cu ft

Unit Pack Cube (UP_CU_5155)

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

A

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level A packing protection.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4310-00-595-3014 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAXJDuty Cycle In Percent100
AAXPCooling System DesignSINGLE
BDMLControl Device TypeAUTOMOTIVE SPEED REGULATOR
AAXGCompressor Quantity1
ZZZTNondefinitive Spec/Std DataMC-2 TYPE
AAYTIntake Connection Quantity1
AKDJPrime Mover TypeGASOLINE ENGINE
AAXYReciprocating Compressor DesignDOUBLE ACTING
BPRZSafety Device TypeRELIEF VALVE
AAZASilencer TypeDISCHARGE
AAYDStage Quantity2


Back to Top
Back to Top