Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
81 1/2D15.50 3P | 3 - Design Control Reference | 2 - Production Item | GORMAN-RUPP COMPANY, THE | 25567 | ![]() |
D11625SHT1-2 | 5 - Replaced / Discontinued | 2 - Production Item | GORMAN-RUPP COMPANY, THE | 25567 | ![]() |
D11625SHT1X2 | 5 - Replaced / Discontinued | 2 - Production Item | GORMAN-RUPP COMPANY, THE | 25567 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
43 | 4320 | 000739916 | A19400 | 17988 | X | M | 3 | A | N | A | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N1H5 | 3 | Q | P | HD | HX | GG | 1 Apr 1991 | |||||||||||||||||||||||
N9BC | 3 | Q | Z | GH | GG | HX | HD | 1 May 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The government does not have adequate data, lacks rights to data, or both, needed to purchase this part from additional sources. Valid AMCs: 1, 2, 3, 4 and 5.
Nuclear Propulsion Items: Items which are used in nuclear power plants or associated systems and which require stringent technical or quality control.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Navy ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | HD | 81 1/2D15.50 3P | 25567 | ![]() | ||||||
3 | 5 | 2 | 1 | HD | D | D11625SHT1-2 | 25567 | ![]() | ||||
1 | 5 | 2 | 1 | HX | B | D11625SHT1X2 | 25567 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Navy ICP, Mechanicsburg, PA 17055-0788
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | AX | 0 | 7 Apr 1976 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 594 | Z | 9 | A | V | Z | M | 128000 | X | 64870 | PUMPS-PWR-NOI-WORKING-HEADS-PARTS |
85
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | A | ZZ | 1 | 000 | 68.8 lbs | 18in x 12in x 10in | 1.300 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ | 00 | O | E | Q | A |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Heated General Purpose – Heated 40 F and above
See J.4.1.b
Any suitable process that is not injurious to the item.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
No requirement.
Unit container is not an acceptable shipping container.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AHZE | Centrifugal Pump Design | MIXED FLOW |
AHZF | Centrifugal Pump Impeller Quantity | 1 |
AHZG | Centrifugal Pump Impeller Suction Type | SINGLE |
AENK | Cooling Method | SELF VENTILATED |
AMPS | Current Rating In Amps | 1.0 |
ACDC | Current Type | AC |
AAYV | Discharge Connection Quantity | 1 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 1.875-12 UN |
AAYW | Discharge Connection Type | THREADED INTERNAL |
AHYW | Discharge Pressure | 12.0 POUNDS PER SQUARE INCH GAGE |
ADZC | Environmental Protection | DRIPPROOF |
CBBL | Features Provided | SELF-PRIMING |
FREQ | Frequency In Hertz | 60.0 |
AHYV | Maximum Discharge Flow Rate | 28.0 GALLONS PER MINUTE |
AAXX | Mounting Type | BASE |
AHYZ | Operating Speed At Rated Capacity | 3450.0 REVOLUTIONS PER MINUTE |
AKNA | Inclosure Type | OPEN |
AAYT | Intake Connection Quantity | 1 |
ASWT | Intake Connection Thread Size And Series/Type Designator | 1.875-12 UN |
AAYU | Intake Connection Type | THREADED INTERNAL |
AAXS | Prime Mover Cooling Medium | AIR |
CSYL | Prime Mover Power Rating | 0.500 HORSEPOWER |
AAXH | Prime Mover Quantity | 1 |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AENC | Pump Quantity | 1 |
AHZA | Pumping Element Operating Position | HORIZONTAL |
FAAZ | Phase | THREE |
ELEC | Voltage In Volts | 440.0 |
AAYD | Stage Quantity | 1 |