Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3672 | 3 - Design Control Reference | 9 - No Longer Used | GOULDS PUMPS INCORPORATED | 25681 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
43 | 4320 | 008382719 | A19400 | 17988 | X | M | 3 | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | AX | 0 | 21 Mar 1967 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 594 | Z | 9 | A | V | Z | M | 128000 | X | 64870 | PUMPS-PWR-NOI-WORKING-HEADS-PARTS |
85
Pumps and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AHZG | Centrifugal Pump Impeller Suction Type | SINGLE |
AHZE | Centrifugal Pump Design | AXIAL FLOW |
AHZF | Centrifugal Pump Impeller Quantity | 1 |
AAYV | Discharge Connection Quantity | 1 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 1.500-11-1/2 NPT |
AAYW | Discharge Connection Type | THREADED INTERNAL |
CBBL | Features Provided | SELF-PRIMING |
AHYV | Maximum Discharge Flow Rate | 85.0 GALLONS PER MINUTE |
AHYZ | Operating Speed At Rated Capacity | 3200.0 REVOLUTIONS PER MINUTE |
AAYT | Intake Connection Quantity | 1 |
ASWT | Intake Connection Thread Size And Series/Type Designator | 1.500-11-1/2 NPT |
AAYU | Intake Connection Type | THREADED INTERNAL |
CSYL | Prime Mover Power Rating | 2.000 HORSEPOWER |
AAXH | Prime Mover Quantity | 1 |
AKDJ | Prime Mover Type | GASOLINE ENGINE |
AAXS | Prime Mover Cooling Medium | AIR |
AENC | Pump Quantity | 1 |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AHYX | Total Head | 50.000 FEET |
AAYD | Stage Quantity | 1 |
AHYY | Suction Lift | 25.000 FEET |