Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
60-11S | 3 - Design Control Reference | 9 - No Longer Used | ITT BELL AND GOSSET-HYDRONICS | 06631 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
43 | 4320 | 010170822 | A19400 | 17988 | X | 4 | 6 | A | N | U | 1 Mar 1976 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G860 | 0 | 0 | C | 1 Apr 1991 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 4 | 75 | D | 60-11S | 06631 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
GSA, FSS/FCSC Washington, DC 20406
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 1 Mar 1976 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
86 |
NASA Kennedy Space Center, Kennedy Space Center, FL 32899
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AHZE | Centrifugal Pump Design | MIXED FLOW |
AHZF | Centrifugal Pump Impeller Quantity | 1 |
AHZG | Centrifugal Pump Impeller Suction Type | SINGLE |
AENK | Cooling Method | SELF VENTILATED |
ACDC | Current Type | AC |
AAYV | Discharge Connection Quantity | 1 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 1.250-11.500 NPT |
AAYW | Discharge Connection Type | THREADED EXTERNAL |
AHYW | Discharge Pressure | 175.0 POUNDS PER SQUARE INCH GAGE |
ADZC | Environmental Protection | DRIPPROOF |
CBBL | Features Provided | SELF-PRIMING |
FREQ | Frequency In Hertz | 60.0 |
AHYV | Maximum Discharge Flow Rate | 50.0 GALLONS PER MINUTE |
AHYZ | Operating Speed At Rated Capacity | 1750.0 REVOLUTIONS PER MINUTE |
AKNA | Inclosure Type | FULLY INCLOSED |
AAYT | Intake Connection Quantity | 1 |
ASWT | Intake Connection Thread Size And Series/Type Designator | 1.250-11.500 NPT |
AAYU | Intake Connection Type | THREADED EXTERNAL |
AAXS | Prime Mover Cooling Medium | AIR |
CSYL | Prime Mover Power Rating | 0.250 HORSEPOWER |
AAXH | Prime Mover Quantity | 1 |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AENC | Pump Quantity | 1 |
AHZA | Pumping Element Operating Position | HORIZONTAL |
FAAZ | Phase | SINGLE |
AHYX | Total Head | 25.000 FEET |
AJAH | Unpackaged Unit Height | 12.500 INCHES NOMINAL |
AJAG | Unpackaged Unit Width | 7.5000 INCHES NOMINAL |
AJAF | Unpackaged Unit Length | 20.000 INCHES NOMINAL |
ELEC | Voltage In Volts | 115.0 AND 230.0 |
AAYD | Stage Quantity | 1 |
AHYY | Suction Lift | 10.000 FEET |