Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MILH82000 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
44 | 4420 | 004918809 | A28500 | 04042 | X | 1 | A | N | U | 22 Mar 1972 |
Furnace, Steam Plant, and Drying Equipment; and Nuclear Reactors
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N2CM | 0 | 0 | V | X | JN | 1 Apr 1991 | ||||||||||||||||||||||||
ZW01 | 1 Sep 2009 |
Not Established
An activity within the Navy is providing depot maintenance support.
INVALID ITEM MANAGEMENT CODE - Items Not Reviewed
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 4 | 1 | 3 | JN | D | MILH82000 | 81349 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Naval Facilities Expeditionary Logistics Center, Port Hueneme, CA 93043
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 98 | 0 | 1 Feb 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JS | M | 72E | Z | 9 | A | B | Z | Z | 000000 | X | 00000 | NO-NMFC-FREIGHT-DESCRIPTION |
Naval ICP, Mechanicsburg, PA 17055-0788
85
Engineer and Material Handling Equipment, Test/Tool sets and Equipment
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
No Rating
No Variation. NMFC and UFCC Match.
Naval Facilities Expenditionary Logistics Center, Code N42, Bldg 1000 23rd Ave, Port Hueneme, CA 93043
SERVICE/AGENCY-REGULATED (Service/Agency use only.) Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures.
Unclassified
1
NAVY: 2C COG CESE Material (Major End Item)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CRMQ | Connection Nominal Diameter | 3.000 INCHES HEATING FLUID INLET |
CRMQ | Connection Nominal Diameter | 3.000 INCHES HEATING FLUID OUTLET |
AWLS | Connection Type | FLANGED PIPE HEATING FLUID INLET |
AWLS | Connection Type | FLANGED PIPE HEATING FLUID OUTLET |
ZZZX | Departure From Cited Designator | AS MODIFIED BY SPECIAL FEATURES |
ABMZ | Diameter | 12.000 INCHES MAXIMUM |
BRXN | Heat Transfer Method | INDIRECT |
HGTH | Height | 48.000 INCHES MAXIMUM |
ZZZT | Nondefinitive Spec/Std Data | 5 SIZE |
MATT | Material | STEEL OVERALL |
ABRY | Length | 192.000 INCHES MAXIMUM |
BZSX | Rated Capacity At Maximum Working Pressure | 21000.0 GALLONS PER HOUR |
FEAT | Special Features | OIL TYPE DF 1 FED SPEC VV-800,HEATER AND EXCHANGER ON SEPARATE SKIDS WITH COMPONENTS AND ACCESSORIES,MIN OUTPUT OF 5,000,000 BTU/HR,FITTINGS TO BE IN ACCORDANCE W/ANSI B31.1.0 FOR 150 PSI 450 DEG F SERVICE,EXTERIOR SURFACE COVERED W/STD THK FIBERGLASS INSULATION,HOSES FURNISHED,HEAT EXCHANGER FURNISHED |
AWMZ | Tube Attachment Method | WELDED BOTH ENDS |
STYL | Style Designator | PLAIN U-TUBE |