4430-00-061-8489

OVEN,THERMAL DRYING,ELECTRIC


4430-00-061-8489 (4430000618489, 000618489)
Part Numbers (2 listings): CDE446S | W0830TYPE2CLASS2STYLE1SIZE5 |
Summary

FSG 44 / FSC 4430

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4430-00-061-8489 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CDE446S3 - Design Control Reference2 - Production ItemKOCH GEORGE SONS LLC  34123      
CDE446S3 - Design Control Reference2 - Production ItemKOCH GEORGE SONS LLC  34123      
W0830TYPE2CLASS2STYLE1SIZE54 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
W0830TYPE2CLASS2STYLE1SIZE54 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberFEDERAL SPECIFICATIONS  81348    CAGE 81348  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 4430-00-061-8489 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
444430000618489T242-B12824XKANA01 Jan 1963
Code Definitions

44

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Furnace, Steam Plant, and Drying Equipment; and Nuclear Reactors

4430

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Industrial Furnaces, Kilns, Lehrs, and Ovens

000618489

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4430-00-061-8489

T242-B

Federal Item Identification Guide (FIIG_4065)

12824

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG C - REFERENCE NUMBER | NSN 4430-00-061-8489 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3322SBDCDE446S  34123  
3414SBDW0830TYPE2CLASS2STYLE1SIZE5  81348   CAGE/81348
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4430-00-061-8489 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59861 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4430-00-061-8489 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
W72DZZAEZJ062600B74250OVENS-INFRA-RED-RAY-HEATING-SUB2
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


W

Less Than Carload (LCL_CD_2760)


Rating Variable

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

E

Air Commodity Code (AIR_CMTY_HDLG_9215)


Engineer supplies, other than those listed under code B.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

062600

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

B

NMFC Sub Item Number (SUB_ITM_NBR_0861)

74250

Uniform Freight Classification (UFC_CD_MODF_3040)

OVENS-INFRA-RED-RAY-HEATING-SUB2

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 4430-00-061-8489 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZZ000
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZ00AZZA
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

A

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level A packing protection.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4430-00-061-8489 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKYDAccessory Components And QuantitySHELVES,ADJUSTABLE 3
BLSYAdjustable OpeningPROVIDED
BJPBCabinet Door Quantity1
BLSZCabinet Fresh Air IntakePROVIDED
BLSRCabinet Double Wall ConstructionPROVIDED
BLSXCabinet Exhaust VentPROVIDED
BHGTCirculation MethodFORCED
ACDCCurrent TypeAC
FREQFrequency In Hertz60.0
BLTBFresh Air Intake Adjustable OpeningPROVIDED
AEHZMaximum Operating Temp500.0 DEG FAHRENHEIT
ZZZTNondefinitive Spec/Std Data2 TYPE AND 2 CLASS AND 1 STYLE AND 5 SIZE
BLSQNormal Operating Temp Range+77.0 TO 500.0 DEG FAHRENHEIT
ABFYOverall Depth56.000 INCHES NOMINAL
AFEFInside Depth48.000 INCHES NOMINAL
AFMQInside Height72.000 INCHES NOMINAL
BLSTInsulated CabinetPROVIDED
ADJTInside Width48.000 INCHES NOMINAL
ABKWOverall Height88.750 INCHES NOMINAL
ABMKOverall Width71.500 INCHES NOMINAL
FAAZPhaseTHREE
ELECVoltage In Volts220.0
BDWWWattage Rating18.0 KILOWATTS
BLSNWork Protection From Heat SourceCOMPLETE
BBWMTemp Control MethodAUTOMATIC
BLTCThermometer TypeMECHANICAL


Back to Top