4520-00-216-2004

HEATING ELEMENT,ELECTRICAL,NONIMMERSION TYPE


4520-00-216-2004 (4520002162004, 002162004)
Part Number (1 listing): 0V1E
Summary

FSG 45 / FSC 4520

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4520-00-216-2004 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0V1E3 - Design Control Reference9 - No Longer UsedACME LABORATORY EQUIPMENT CO  00181    CAGE 00181  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 4520-00-216-2004 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
454520002162004A0190029427XM9ANU1 Jan 1963
Code Definitions

45

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Plumbing, Heating, and Waste Disposal Equipment

4520

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Space and Water Heating Equipment

002162004

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4520-00-216-2004

A01900

Federal Item Identification Guide (FIIG_4065)

29427

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4520-00-216-2004 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4520-00-216-2004 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2KX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

KX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Philadelphia, Philiadelphia, PA 19101

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4520-00-216-2004 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
W658Z9AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


W

Less Than Carload (LCL_CD_2760)


Rating Variable

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4520-00-216-2004 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHHKElement Quantity4
ABJAElement Radiation SpectrumNONINFRARED
FREQFrequency In Hertz60.0
ZZZVFsc Application DataOVEN,LABORATORY,DRYING
ABNRHeat Quantity1
AAQLBody StyleFINNED, TUBULAR, TERMINAL'S AT EACH END
MATTMaterialNICKEL SHEATH AND CHROMIUM SHEATH
AZQHMaximum Wattage Rating In Watts300.0 SINGLE VOLTAGE
AALXMounting Method StyleTERMINAL MOUNTED
FAAZPhaseSINGLE SINGLE VOLTAGE
CSBHVoltage In Volts And Current Type110.0 AC 1ST VOLTAGE OR 110.0 DC 1ST VOLTAGE
CSBHVoltage In Volts And Current Type220.0 AC 2ND VOLTAGE OR 220.0 DC 2ND VOLTAGE


Back to Top