4520-00-371-2665

HEATING ELEMENT,ELECTRICAL,NONIMMERSION TYPE


4520-00-371-2665 (4520003712665, 003712665)
Part Number (1 listing): B001459-1
Summary

FSG 45 / FSC 4520

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 7 Mar 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4520-00-371-2665 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
B001459-13 - Design Control Reference2 - Production ItemMOOG INC.  19156    CAGE 19156  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4520-00-371-2665 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
454520003712665A0190029427X1ANU7 Mar 1969
Code Definitions

45

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Plumbing, Heating, and Waste Disposal Equipment

4520

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Space and Water Heating Equipment

003712665

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4520-00-371-2665

A01900

Federal Item Identification Guide (FIIG_4065)

29427

Item Naming Code (INC_4080)

7 Mar 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 4520-00-371-2665 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 4520-00-371-2665 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325HHDB001459-1  19156   CAGE/19156
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

HH

Reference Number Action Activity Code (RNAAC_2900)


Navy ICP, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4520-00-371-2665 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2AX012 Sep 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

AX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43216-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

12 Sep 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4520-00-371-2665 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HH658Z9AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

HH

Originating Activity Code (ORIG_ACTY_CD_4210)


Navy ICP, Mechanicsburg, PA 17055-0788

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4520-00-371-2665 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9CYU1EA0
Code Definitions

S9C

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43215 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4520-00-371-2665 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABJSElement Connection StyleWIRE LEAD
ABJAElement Radiation SpectrumNONINFRARED
BHHKElement Quantity1
ABJMHeat Control TypeTHERMOSTAT
ABNRHeat Quantity1
AAQLBody StyleOVEN TYPE
MATTMaterialNICKEL ALLOY RESISTANCE WIRE
MATTMaterialRUBBER SYNTHETIC RESISTANCE WIRE EMBEDDING/SUPPORT INSULATION
AZQHMaximum Wattage Rating In Watts12.5 SINGLE VOLTAGE
AALXMounting Method StyleTERMINAL MOUNTED
ABRYLength3.000 INCHES NOMINAL
ABHPOverall Length9.000 INCHES NOMINAL
CSBHVoltage In Volts And Current Type60.0 DC SINGLE VOLTAGE
ABNSWatt Density Rating4.5 PER SQUARE INCH SINGLE VOLTAGE
ABGLWidth1.250 INCHES NOMINAL
ABJVTerminal Arrangement StyleONE AT EACH END
ABKFTerminal Box Environmental ProtectionMOISTURE RESISTANT
ABJTTerminal Length6.000 INCHES NOMINAL
AARATerminal Quantity2
ABJNThermostat Range+87.7/+110.0 DEG CELSIUS


Back to Top