Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
UH73-2HA | 3 - Design Control Reference | 2 - Production Item | HDT EXPEDITIONARY SYSTEMS, INC. | 92878 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
45 | 4520 | 008354513 | A01300 | 03228 | X | K | A | N | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Jul 1995 | |||||||||||||||||||||||||||||
ZR01 | 1 Dec 2007 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | AX | 0 | 11 Mar 1972 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
J | 752 | Z | 9 | A | B | Z | W | 062250 | Z | 12590 | HEATERS-INDUSTRIAL-RADIANT |
100.2
Prefabricated Structures & Scaffolding
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABBA | Air Circulation Device | PROPELLER FAN |
ABBE | Circulated Air Type | HEATED |
AMPS | Current Rating In Amps | 3.0 |
ACDC | Current Type | AC |
AEJZ | Depth | 11.312 INCHES NOMINAL |
ABFH | Flue Connection Location | ONREARCENTER6.50IN.FROMFLOOR |
FREQ | Frequency In Hertz | 60.0 |
CQTY | Fuel Consumption Rate Per Hour | 0.6 GALLONS |
CSGC | Fuel Feed Method | INTERNAL PUMP |
FUEL | Fuel Type | 80/87 OCTANE GASOLINE AND 91/96 OCTANE GASOLINE |
CQXD | Heat Delivery Rate | 50000.0 BRITISH THERMAL UNIT |
ABAM | Heat Medium Type | AIR |
BDXJ | Heating Element Type | COMBUSTION CHAMBER |
HGTH | Height | 30.375 INCHES NOMINAL |
BLJC | Ignition Method | ELECTRODE |
ABBD | Maximum Air Flow Rate | 500.0 CUBIC FEET PER MINUTE |
AAXX | Mounting Type | FLOOR SURFACE, FREE STANDING, NONDUCTED |
ALYC | Operating Control Type | THERMOSTATIC |
CQSJ | Inclosure Material | STEEL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
NMBR | Quantity | 1 |
ABFG | Radio Interference Suppression Type | ARMY, MIL-E-53301, RADIO SUPPRESSION |
FAAZ | Phase | SINGLE |
FEAT | Special Features | CONTROL INDICATOR; SWITCHES FOR MOTOR COMBUSTION,OFF-ON,RE-SET,THERMOSTATIC OVER HEAT,THERMOSTATIC VENTILATING MOTOR,VENT HEAT; THERMOSTAT |
ELEC | Voltage In Volts | 115.0 |
ABGL | Width | 23.875 INCHES NOMINAL |
ABBB | Speed Adjustments | SINGLE SPEED |
SFTT | Surface Treatment | PAINT |