4540-01-121-4968

HEATING ELEMENT,ELECTRICAL,IMMERSION TYPE


4540-01-121-4968 (4540011214968, 011214968)
Part Number (1 listing): TM-3065-480V-6000W-3PD
Summary

FSG 45 / FSC 4540

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 6 Nov 1981

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4540-01-121-4968 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TM-3065-480V-6000W-3PD3 - Design Control Reference2 - Production ItemCHROMALOX, INC.  65586    CAGE 65586  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4540-01-121-4968 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
454540011214968A0190011327XKANA6 Nov 1981
Code Definitions

45

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Plumbing, Heating, and Waste Disposal Equipment

4540

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Waste Disposal Equipment

011214968

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4540-01-121-4968

A01900

Federal Item Identification Guide (FIIG_4065)

11327

Item Naming Code (INC_4080)

6 Nov 1981

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 4540-01-121-4968 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
C056C0553H1 Jul 2010
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4540-01-121-4968 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 Nov 1981
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Nov 1981

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4540-01-121-4968 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4540-01-121-4968 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
GPZNCZU1CEA0
Code Definitions

ZNC

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Commanding Officer, USCG Surface Force Logistics Center, Code 028, Mil Stop 25, 2401 Hawkins Point Road, Baltimore, MD 21226-5000

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

C

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions; MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions; NAVY: Field Activity Control Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4540-01-121-4968 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABHSEffective Heating Length18.062 INCHES NOMINAL
ABJAElement Radiation SpectrumNONINFRARED
BHHKElement Quantity3
ABJSElement Connection StyleTERMINAL SCREW
ABKGBolt Circle Diameter6.000 INCHES NOMINAL
ABNTConduit Opening Size1.000 INCHES NOMINAL
AGAVEnd Item IdentificationUSED ON EMERGENCY DIESEL ENGINE ONBOARD 270 FT WMEC COAST GUARD VESSELS
ABKKFlange Diameter7.500 INCHES NOMINAL
ABKUFlange Thickness0.938 INCHES NOMINAL
FREQFrequency In Hertz60.0
ABNRHeat Quantity1
AAUBHole Diameter0.750 INCHES NOMINAL
ABKTHole Or Slot Quantity4
AAQLBody StyleFLANGE, TYPE
MATTMaterialCOPPER SHEATH
AZQHMaximum Wattage Rating In Watts6000.0 SINGLE VOLTAGE
AALXMounting Method StyleFLANGE TYPE MOUNTING FACILITY
ABRYLength18.062 INCHES NOMINAL
ABHPOverall Length21.562 INCHES NOMINAL
FAAZPhaseTHREE SINGLE VOLTAGE
CSBHVoltage In Volts And Current Type480.0 AC SINGLE VOLTAGE
ABNSWatt Density Rating45.0 PER SQUARE INCH SINGLE VOLTAGE
AARATerminal Quantity3