Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
90C02-2344 | 3 - Design Control Reference | 2 - Production Item | CARRIER CORPORATION | 10855 | ![]() |
90SM-125-0001 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | CARRIER CORPORATION | 10855 | ![]() |
90SM-125-0001 ITEM 55 | 5 - Replaced / Discontinued | 2 - Production Item | CARRIER CORPORATION | 10855 | ![]() |
2-36-22-1 | 5 - Replaced / Discontinued | 2 - Production Item | WATLOW MISSOURI, INC. | 9F951 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
45 | 4540 | 013721493 | A01900 | 11327 | X | 1 | A | N | A | 3 Mar 1993 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BZ | N9ZD | 3 | Z | Z | GH | HD | 1 Sep 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 6 | AX | 90C02-2344 | 10855 | ![]() | ||||||
5 | 1 | 6 | AX | 90SM-125-0001 | 10855 | ![]() | ||||||
5 | 2 | 6 | AX | 90SM-125-0001 ITEM 55 | 10855 | ![]() | ||||||
5 | 2 | 6 | AX | 2-36-22-1 | 9F951 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43216-5000
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 3 Mar 1993 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AX | 658 | Z | 9 | A | B | Z | P | 026040 | X | 34830 | ELEMENTS-IMMERSION-HEATING |
Defense Supply Center Columbus, Columbus, OH 43216-5000
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | 000 |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | JC | X | E5 | 00 | 00 | E | H | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves
As required to protect the item or elements of the package
ASTM-D5118, fiberboard box.
No requirement.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished using boxes fabricated in accordance with ASTMD5118, class weather-resistant.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABHS | Effective Heating Length | 13.750 INCHES NOMINAL |
ABJA | Element Radiation Spectrum | NONINFRARED |
BHHK | Element Quantity | 1 |
ABJS | Element Connection Style | WIRE LEAD |
FREQ | Frequency In Hertz | 60.0 |
ABNR | Heat Quantity | 1 |
AAQL | Body Style | TUBULAR, SCREW TYPE |
MATT | Material | STEEL CORROSION RESISTING SHEATH |
AZQH | Maximum Wattage Rating In Watts | 500.0 SINGLE VOLTAGE |
ABKP | Mounting Facility Length | 0.500 INCHES NOMINAL |
AALX | Mounting Method Style | SCREW PLUG OR BUSHING TYPE MOUNTING FACILITY |
ABRY | Length | 14.750 INCHES NOMINAL |
FEAT | Special Features | 1.625-12 SCREW PLUG SIZE; 1.875 IN. HEX WRENCHING FACILITY; VITON O-RING SEAL PROVIDED |
ABHP | Overall Length | 19.093 INCHES NOMINAL |
FAAZ | Phase | SINGLE SINGLE VOLTAGE |
THSD | Thread Series Designator | UNS MOUNTING FACILITY |
CSBH | Voltage In Volts And Current Type | 115.0 AC SINGLE VOLTAGE OR 230.0 AC SINGLE VOLTAGE |
ABNS | Watt Density Rating | 7.9 PER SQUARE INCH SINGLE VOLTAGE |
ABKF | Terminal Box Environmental Protection | MOISTURE RESISTANT |
ABJT | Terminal Length | 12.000 INCHES NOMINAL |
AARA | Terminal Quantity | 3 |