4610-01-584-8707

WATER PURIFICATION UNIT,UNMOUNTED


4610-01-584-8707 (4610015848707, 015848707)
Part Number (1 listing): AWI-55-001-SET
Summary

FSG 46 / FSC 4610

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 10 May 2010

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 4610-01-584-8707 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AWI-55-001-SET3 - Design Control Reference2 - Production ItemASPEN WATER, INC.  1QP02      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 4610-01-584-8707 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
464610015848707T227-C08337X43ANAA010 May 2010
Code Definitions

46

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Water Purification and Sewage Treatment Equipment

4610

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Water Purification Equipment

015848707

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 4610-01-584-8707

T227-C

Federal Item Identification Guide (FIIG_4065)

08337

Item Naming Code (INC_4080)

10 May 2010

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 4610-01-584-8707 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A102A103000DCNBS1 Sep 2011
F8SQFOO4000DCNTO1 Sep 2011
MS22000DCN1 Sep 2011
NJQ4000DCN1 Sep 2011
SC0100PDCN1 Sep 2011
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

0

Nonconsumable Item Material Support Code (NIMSC_0076)


DLIS File Conversion Code. This code was assigned by DLIS to existing wholesale interservice supply support agreement (WISSA) type recording (LOA 8D) during initial file conversion program. This code is reassigned to code 1, 2, 3, 5, 6 or 8 upon completion of item review. The SICA CMD will reflect the SOS/SOSM and AAC compatible with the PICA. The PICA will not be entered in the DAAS IMM field.

D

Item Management Code (IMC_2744)


Major End Items of Equipment: Items of such importance to the operations readiness of operating units that they are subject to continuing centralized individual item management and asset control throughout all command and support echelons.

P

Nonconsumable Item Material Support Code (NIMSC_0076)


Total depot maintenance is being accomplished by commercial contract.

CNDSOR

Depot Source of Repair Codes (DSOR_0903)


Contract, Contiguous United States (CONUS)

TOCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Special Operations Force Support Agency (SOFSA) Lexington, KY 40516-9723

BS

Supplementary Receivers (SUPPLM_RCVR_2534)


USAMC Data Management Center, Redstone Arsenal, AL 35898-5239


FLIS - SEG C - REFERENCE NUMBER | NSN 4610-01-584-8707 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZAWI-55-001-SET  1QP02  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 4610-01-584-8707 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597010 May 2010
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 May 2010

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 4610-01-584-8707 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TK
Code Definitions

TK

Originating Activity Code (ORIG_ACTY_CD_4210)


HQ AFMC/GLSC 401 SCM/GUMB, Wright-Patterson AFB, OH 45433-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 4610-01-584-8707 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAH9DCU1SE0
DMH9DCU1SE0
DNH9DCU1HSE0
DFH9DCU1SSE0
DJH9DCU1SE0
Code Definitions

H9D

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Special Operations Forces Support Activity (SOFSA), BLDG 220, 5749 Briar Hill Rd, Lexington, KY 40516-9721

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

SE

Unit of Issue (UI_3050)


Set - A collection of matched or related items issued as a single item of supply, i.e., tool sets, instrument sets, and matched sets. Use only when the term “set” is a part of the item name.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

S

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DJ

Service / Agency Code (MOE_CD_2833)


HQ United States Special Operations Command (HQ USSOCOM)


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 4610-01-584-8707 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKDJPrime Mover TypeELECTRIC MOTOR
ACDCCurrent TypeAC/DC
ELECVoltage In Volts110.0
ELECVoltage In Volts220.0
ELECVoltage In Volts24.0
FREQFrequency In Hertz50.0
FREQFrequency In Hertz60.0
FAAZPhaseSINGLE
FEATSpecial FeaturesTHE ASPEN 5500M WATER PURIFICATION SYSTEM WILL SUPPLY 4,000 TO 5,000 GALLONS PER DAY (BETWEEN 160 TO 210 GALLONS PER HOUR) OF HIGHLY PURIFIED WATER FROM VIRTUALLY ANY NON-SALINE WATER SOURCE. OPERATES ON 90 TO 260 VOLTS AC AT 50 OR 60 HERTZ AS WELL AS 10 TO 30 VOLTS DC, VIRTUALLY ANY ONE PHASE POWER SOURCE. THE MILITARY VERSION COMES STANDARD WITH A 24-VOLT DC INPUT. POWER CORDS WITH MILITARY TYPE QUICK-CONNECTS ARE PROVIDED. WATER CAN BE DRAWN FROM DITCHES, RIVERS, LAKES OR STANDING WATER THAT MAY CONTAIN CHEMICAL AND/OR BIOLOGICAL CONTAMINATION. BOTH INTERLOCKING CASES ARE 43X 28X14. THE APPROXIMATE DRY WEIGHT OF THE WATER TREATMENT UNIT IS 210 LBS, AND THE ACCESSORY CASE IS APPROXIMATELY 110 LBS. TWO STAGE FILTRATION. THE FIRST STAGE REMOVES SAND, DIRT AND VERY FINE PARTICLES DOWN TO 5 MICRONS IN SIZE. THE SECOND STAGE EFFECTIVELY REMOVES HARMFUL MICROORGANISMS SUCH AS PARAMECIUM, AMOEBA, GIARDIA, CRYPTOSPORIDIUM AND OTHER SMALL MATTER DOWN TO 1 MICRON


Back to Top
Back to Top